background image

 

 

Copyright 2021 EtherWAN Systems, Inc.

  

  Page 1 

 

All Rights Reserved 

EMC1600rev. 1.0 

12/22/2021 
 

W70G-EMC1600Q3

 

 

 

EMC1600 Media Converter and Ethernet Extender Chassis

 

Installation Guide

 

 

Unpacking 

Open the carton and unpack the items. Your 
package should include: 

 

16-Bay Media Converter Chassis 

 

Power cords  

 

User’s Manual

 

 

Brackets & Bracket screws 

 

Media converter carriers, fitted to each bay 

 

If any items are missing or damaged, notify your 
EtherWAN representative.  
 

Select a Location 

The installation site should be free of extreme 
temperatures, humidity, or excessive 

electromagnetic interference. Specifically, the 
site should meet the following requirements: 

 

The ambient temperature should be between 
32 and 113 degrees Fahrenheit (0 to 45 
degrees Celsius). 

 

The relative humidity should be at least 5% 
and less than 95 percent, non-condensing. 

 

Surrounding electrical devices should not 
exceed the electromagnetic field (EMC) 
standards for IEC 801 3, Level 2 (3V/M) field 
strength. 

 

Make sure that the equipment receives 
adequate ventilation. Do not block the 
ventilation holes on each side of the 

equipment or the fan exhaust port on the 
side or rear of the equipment. 

Rack Mounting 

Use the rackmount brackets and screws to install 

the chassis into any EIA 19” standard rack.

 

 

Place the brackets on the sides of the chassis 

so that the screw holes are aligned. Use the 
bracket screws to securely attach the 
brackets to the chassis. 

 

Position the chassis into the rack. Align the 
brackets to the side holes on the rack and 

use rack screws to secure the chassis to the 
rack.  

 

Installing Components 

Each bay is equipped with a holding tray, 
secured to the chassis by a retaining screw. To 
install a media converter or Ethernet extender:  
 

1)

 

Loosen the retaining screw and pull the 

holding tray out. 

2)

 

Remove the inner face plate from the 
holding tray.  

3)

 

Fit the component into the holding tray, and 
then slide the holding tray into the bay.  

4)

 

Tighten the retaining screw to secure the 
holding tray and component in place. 

 

 
NOTE:

 Do not insert a media converter or 

Ethernet extender into the chassis directly 

without using the supplied holding trays. The 
holding trays ensure correct placement of 
components, and provide electrical insulation.  
 

Connect Power 

The chassis provides dual power supplies for 
redundancy and load sharing. However, only one 
power supply is needed to operate the chassis.

 

AC Power:

 Connect the supplied AC power cords 

to the receptacles power supply. Plug the cords 
in to a standard AC outlet with a voltage range 
from 100~240VAC. 

Power Consumption 

Chassis: 5.4W Max. 
 
 
 

Relay Output Alarm 

The chassis provides a 3-pin relay dry contact 
located at the rear panel of the chassis for 

signaling of a power failure. The relay output 
can be connected to an alarm signaling device. 
The relay alarm will be triggered when the 
system power falls below 10.8VDC. The relay 
logic will apply for both single and dual power 

operation. Current is 0.6 Amps at 30VDC. 

 

Normal state: 3 & 2 open, 2 & 1 closed 
Alarm state: 3 & 2 closed, 2 & 1 open 

 

 