background image

 

 

 

 

User’s Guide 

 

ED3501 Industrial Ethernet Extender 

 

 

 

 

 

 

 

FastFind Links 

 

Introduction 

Unpacking and Installation 

 

Summary of Contents for ED3501

Page 1: ...User s Guide ED3501 Industrial Ethernet Extender FastFind Links Introduction Unpacking and Installation ...

Page 2: ...t to change without notice EtherWAN is not liable for any errors or omissions contained herein or for resulting damage in connection with the information provided in this manual Registered Trademarks The following words and phrases are registered Trademarks of EtherWAN Systems Inc EtherOS Ethernet to the World All other trademarks are property of their respective owners Warranty For details on the...

Page 3: ... the Ethernet network This document assumes the reader has moderate hardware computer and Internet skills Document Revision Level This section provides a history of the revision changes to this document Revision Document Version Date Description A Version 1 08 06 2015 Initial release Changes in this Revision N A this is first version of this document ...

Page 4: ...propriate precautions such as not opening or touching hazardous areas of the equipment could result in injury or death Typographic Conventions This guide also uses the following typographic conventions Convention Description Bold Indicates text on a window other than the window title including menus menu options buttons fields and labels Italic Indicates a variable which is a placeholder for actua...

Page 5: ...llation 10 Unpacking the Hardware 11 Hardware Features 11 Front Panel 11 Rear Panel 14 Bottom Panels 15 Installing the Industrial Ethernet Extender 15 Preparing the Site 16 Installing the Industrial Ethernet Extender 16 Connecting to the 10 100 Mbps RJ 45 Port 17 Connecting to Ethernet Extender Port 17 Checking the Installation 17 Applying AC Power 17 3 Troubleshooting 20 Troubleshooting Chart 21 ...

Page 6: ...vi ED3501 Industrial Ethernet Extender User Guide Industrial Ethernet Extender Integrity 22 Auto Negotiation 22 Technology 23 Power 23 Mechanical 23 Interface 24 Environment 25 Regulatory Approvals 25 ...

Page 7: ...c Your EtherWAN Industrial Ethernet Extender is a state of the art IEEE compliant network solution designed for users who require high performance to eliminate bottlenecks and increase productivity To simplify installation the Industrial Ethernet Extender is shipped ready for use Key Features page 8 Quick Start Guide page 9 Figure 1 1 ED3501 Industrial Ethernet Extender ...

Page 8: ...f speed and duplex mode on Ethernet port Auto MDIX on Ethernet port Complies with IEEE 802 3 10Base T and IEEE 802 3u 100Base TX standards One Ethernet Extender port with RJ 11 connector or Termianl Block Ethernet Extender port auto senses the speed DIP switch for configuring Ethernet Extender Auto or Local mode Symmetic or Asymmetric mode and Performance or Standard mode Status LEDs External AC t...

Page 9: ...orage or other network device Connect the other end to a 10 100 Mbps RJ 45 port on the Industrial Ethernet Extender 10 100 Mbps RJ 45 Port page 11 and Connecting to the 10 100 Mbps RJ 45 Port page 17 3 Connect to the Ethernet Extender Port Insert the voice grade copper wire between one pair of Ethernet Extenders via Ethernet Extender port RJ 11 connector or Terminal Block 4 Power On Connect the fe...

Page 10: ...er Guide 2 Unpacking and Installation Topics This chapter describes how to unpack and install the ED3501 Industrial Ethernet Extender Unpacking the Hardware page 11 Hardware Features page 11 Installing the Industrial Ethernet Extender page 15 ...

Page 11: ... The following sections describe the hardware features of the ED3501 Industrial Ethernet Extender Front Panel Figure 2 1 shows the front panels of the ED3501 Industrial Ethernet Extender Figure 2 1 Front Panel of the ED3501 Industrial Ethernet Extender 10 100 Mbps RJ 45 Port The ED3501 Industrial Ethernet Extender has one 10 100 Mbps RJ 45 port see Figure 2 1 This port is auto sensing auto MDIX 10...

Page 12: ...e without requiring user intervention Ethernet Extender Port The ED3501 Industrial Ethernet Extender has one Ethernet Extender port RJ 11 connector or Terminal Block see Figure 2 1 Insert the voice grade copper wire between one pair of Ethernet Extenders via Ethernet Extender port RJ 11 connector or Terminal Block One device must be set to LOC mode and the other to Auto mode when two devices are c...

Page 13: ...wer and link activity status Table 2 1 summarizes the LEDs on the Industrial Ethernet Extender Ethernet Extender Connection The RJ 11 and Terminal Block port pinouts Pin 3 Tip Pin 4 Ring Use a telephone line to connect two RJ 11 or Terminal Block ports between two Hardened Ethernet Extenders ...

Page 14: ...een ON Local mode SYM Green ON Symmetric mode ASM Green ON Asymmetric mode Line Speed Green ON Displays the link speed in Mbps 10 100TX Port Link Activity Green ON Valid network connection OFF No data transmission on port Flashing Port is sending or receiving data Speed Yellow ON Link speed at 100Mbps OFF Link speed at 10Mbps Rear Panel The ED3501 rear panel has a receptacle for connecting the sup...

Page 15: ...n Installing the Industrial Ethernet Extender Industrial Ethernet Extender installation involves the following steps 1 Preparing the site See page 16 2 Installing the Industrial Ethernet Extender See page 16 3 Connecting to the 10 100 Mbps RJ 45 Port See page 17 4 Connecting to Ethernet Extender Port See page 17 5 Checking the installation See page 17 6 Applying AC power See page 17 ...

Page 16: ...he Industrial Ethernet Extender away from heat sources such as direct sunlight warm air exhausts hot air vents and heaters Operating humidity The installation location should have a maximum relative humidity of 95 non condensing Ventilation Do not restrict airflow by covering or obstructing the rear and side panels of the Industrial Ethernet Extender Keep at least 2 inches 5 08 centimeters free on...

Page 17: ...net Extender port Insert the voice grade copper wire between one pair of Ethernet Extenders via Ethernet Extender port RJ 11 connector or Terminal Block One device must be set to LOC mode and the other to Auto mode when two devices are connected Checking the Installation Before you apply power Inspect the equipment thoroughly Verify that all cables are installed correctly Check cable routing to ma...

Page 18: ...elf Test POST After the Industrial Ethernet Extender passes the POST the Link Activity LEDs for every port connected to a device go ON The Industrial Ethernet Extender is now functional and ready to pass data If the Power LED is not ON check that the power adapter is plugged in correctly and that the power source is good and not controlled by a wall switch If this does not resolve the problem see ...

Page 19: ...19 ED3501 Industrial Ethernet Extender User Guide Troubleshooting ...

Page 20: ...l Ethernet Extender User Guide 3 Troubleshooting Topics This chapter provides information about troubleshooting the Industrial Ethernet Extender Troubleshooting Chart page 21 Additional Troubleshooting Suggestions page 22 ...

Page 21: ...roblem Half or full duplex setting on the Industrial Ethernet Extender and the connected device are not the same Configure the Industrial Ethernet Extender and the attached device to auto negotiate A segment or device is not recognized as part of the network One or more devices are not connected properly or cabling does not meet Ethernet guidelines Verify that the cabling is correct Be sure all co...

Page 22: ...ts and other physical aspects of the installation do not exceed the Ethernet limitations Industrial Ethernet Extender Integrity If required verify the integrity of the Industrial Ethernet Extender by resetting it Auto Negotiation The 10 100 Mbps ports negotiate the correct duplex mode and speed since the Industrial Ethernet Extender is configured for auto negotiation this is the Industrial Etherne...

Page 23: ... 100 Mbps 148 810 pps Processing Type Store and Forward Half duplex back pressure and IEEE802 3x full duplex flow control Auto Negotiation Auto MDI MDIX Power Specification Description Power Input 12 VDC DC Jack Power Consumption 4 2 W Max Mechanical Specification Description Casing Aluminum case IP30 Dimensions 80 3 mm W x 109 2 mm D x 23 8 mm H 3 16 W x 4 3 D x 0 94 H Weight 150 g 0 33 lb Instal...

Page 24: ...y Per RMT LOC SYM ASM Line Speed The data rates will vary according to the quality of the connected cable The information below is only for reference of applications Distance m Data Rate Mbps 300 100 400 80 600 60 800 40 2600 1 This distance data rate information is measured according testing standard in EtherWAN laboratory The actual installation will be affected by the quality of copper wire and...

Page 25: ...on ISO Manufactured in an ISO9001 facility Safety UL60950 1 EN60950 1 EMI FCC Part 15B Class A EN61000 6 4 EN55022 EN61000 3 2 EN61000 3 3 EMS EN61000 6 2 EN61000 4 2 ESD Standard EN61000 4 3 Radiated RFI Standards EN61000 4 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards Environmental Test Compliance IEC60068 2 6 Fc Vibration Re...

Page 26: ...al or consequential damages due to omissions or errors The information and specifications in this document are subject to change without notice Copyright 2018 All Rights Reserved All trademarks and registered trademarks are the property of their respective owners ED3501 Industrial Ethernet Extender User Guide August 16 2018 Document version Version 1 2 USA Office 4570 E Eisenhower Circle Anaheim C...

Reviews: