Operation & Software Manual
166
Direct Drives & Systems
Chapter C: System functions
ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Caution:
This command must be used with the
utmost prudence
, since movement speed is very high.
Although the STE command is not an alias, the syntax STE.1+=1000 or STE.1-=1000 are allowed, in order to
make
relative
jump movements, because an absolute jump movement can be dangerous if the motor is far
away from the position to reach.
Examples:
STE.1+=1000
;
Relative
jump movement. the motor realizes a jump movement of 1000 increments
in the positive direction.
STE.1=1000
;
Absolute
jump movement. The motor makes a jump movement from its actual
position to the position of 1000 increments.
13.3.9 BRK and STP commands
The
BRK
command (
BR
a
K
e) stops a movement with the deceleration programmed in parameter K206. It is
also used with infinite rotary movement (refer to
).
The
STP
command (
ST
o
P
) behaves the same way as BRK but the deceleration is infinite. The braking is then
very sudden. This command is to be used only in case of emergency.
Caution:
The sudden deceleration set with the STP command can damage the mechanical parts of the
system.
Note:
BRK and STP commands do not stop the sequence; thus, the movements defined in a sequence
will be executed.
13.3.10 Parameters defining units scales
Parameter
K50
defines the unit scale movements:
Parameter K50:
The POS, SPD and ACC commands are used respectively to determine a position to reach, a speed or an
acceleration. The arguments of these commands must be given in a unit called
user increment
. The
Command format
[s]
<p1>
Comment
Units
STE.<axis>[s] = <p1>
Sign + or -
or nothing
-2
31
to (2
31
-1)
Performs a step movement of the length contained in <p1>
[upi]
[rupi]
Available on
DSC2P
DSC2V
DSCDP
DSCDL
DSCDM
Command format
Comment
BRK.<axis>
Stops the movement using the deceleration programmed in parameter K206 but it does not stop the sequence.
Stops an infinite rotary movement.
STP.<axis>
Stops the movement using an infinite deceleration but it does not stop the sequence.
Available on
DSC2P
DSC2V
DSCDP
DSCDL
DSCDM
K
Name
Comment
K50
Set point
calculator shift
Enables the diminution of the cinematic quantities values. 1dpi = 2
K50
* 1upi
Depth 0 for primary encoder and depth 1 for secondary encoder
(depth 1 is ONLY available on DSC2P
and DSC2V)