The Retrofit
7
Attach New Power Harness
1:
Connect the old power connector to the new power harness adapter found in the kit. The
connectors are keyed - the power connectors only fit one way.
2:
Run the green ground wire from the power harness adapter between the bus bar and the
enclosure wall avoiding any interference with other wires in the enclosure.
3:
Carefully route the ground wire to any open terminal in a grounding strip inside the enclosure.
Grounding terminal screws can be loosened or tightened with a flat-blade or square drive
screwdriver.
4:
Use a wire tie to secure the ground wire to the wires that travel from the mated power harness
connectors.
New Power Harness
Run Ground behind bus bar
Secure Ground in rack
ground terminal