background image

The Response ConverterTM network interface allows you to convert 192 DMX512 signals
to AMX192 or 192 AMX192 signals to DMX512. The compact interface box features an
optically isolated DMX512 link and a 100 hertz output update rate. This manual provides
information on all Response Converter controls, connectors and indicators.

To use Response Converter, follow these steps:

1. Plug power cable into a 120 VAC outlet.
2. For DMX512 to AMX192 operation, set DIP switch 3 down and switch 4 up. If optical

isolation is desired, set DIP switch 1 up. For AMX192 to DMX512 operation, set DIP
switch 1 down, switch 3 up and switch 4 up.

3. Press Reset.
4. Insert input and output cables into appropriate connectors.
5. Set number switches to starting dimmer output number (see page 2).
6. If Response Converter is the last device in a DMX512 data link, set DMX512

terminator switch 

On 

(right). In AMX192 to DMX512 mode, leave terminator switch 

Off

(left).

7. See following pages for adjustment pot settings and additional information on switch

functions and settings.

Note: When data flow is interrupted, all outputs fade to zero percent after three minutes.

11

Converter

U S E R   M A N U A L

TM

3

2

1

9 8 7 6

5

4

3

2

1

0

9 8 7 6

5

4

1      2      3      4      5      6      7      8

PUSH

3

2

1

9 8 7 6

5

4

0

3

2

1

9 8 7 6

5

4

0

PUSH

11

DMX512 Input

DMX512 Output

AMX192 Output

AMX192 Input

Reset switch

Indicator LEDs

DMX512 termination switch

Adjustment pots

DIP switches

Number switches

AC power cable

Reviews: