A
Status Messages
21
Appendix A
Status Messages
Below is a list of status messages that may appear on your Qui Control Station LCD.
If any of these messages appear and you are not sure how to correct the situation,
immediately
cease use of your system
and
contact the ETC Rigging Installer who installed your system or
contact ETC Technical Services at the appropriate office mentioned on
.
For any message that is not included in the table below, contact your system installer or
ETC technical services
.
Message
Corrective Action
At Trim
Release up/down button. Press again to move motor.
Cycle Power
Turn the keyswitch to the “OFF” position, wait 5 seconds, then turn to the “ON” position.
E-Stop
Verify that the area is safe. See accompanying message to determine which button is
pressed.
External
Verify that the area is safe. Release the external E-Stop button.
Hard Lower Limit
The lower limit has been reached. Move the motor in the up direction.
Hard Upper Limit
The upper limit has been reached. Move the motor in the down direction.
High Trim
The user-defined upper limit has been reached. Move the motor in the down direction or set
High Trim to a different position.
Inspection due today
A system inspection is due today. Schedule a system inspection as soon as possible.
Inspection due in
A number of days accompanies this. A system inspection is due in this many days.
Inspection overdu
A system inspection is overdue. Schedule a system inspection as soon as possible.
Load too heavy
Reduce weight on batten or re-record the load profile. Look for obstructions that may have
increased the load.
Load too light
Check to see that load is not resting on something. Increase load or re-record profile.
Local
Verify that the area is safe. Release the control station E-Stop button.
Local Down Stuck
Cycle power with no buttons pressed. If error recurs, contact your system installer or ETC
Technical Services.
Local Up Stuck
Cycle power with no buttons pressed. If error recurs, contact your system installer or ETC
Technical Services.
Low Trim
The user-defined lower limit has been reached. Move the motor in the up direction or set Low
Trim to a different position.
Man Switch Stuck
Cycle power with no buttons pressed. If error recurs, contact your system installer or ETC
Technical Services.
Low Limit Override
Return batten to normal operating range. Release override button.
Max Load Exceeded
Reduce weight on batten. Look for obstructions that may have increased the load.
Motor Over Temp
Wait for motor to cool down. If message remains after 10 minutes, contact your system
installer or ETC Technical Services.
Multiple
Verify that the area is safe. Release all E-Stop buttons.
Not Responding
Make sure the respective motor is powered and connected to the control system. If problem
persists, contact your system installer or ETC Technical Services.
OTrav Lim Override
Return batten to normal operating range. Release override button.
Overload
Reduce the load on the batten.
RC Bypass Fault
Disconnect remote control. Contact your system installer or ETC Technical Services.
Release Button
Check to see that the area is safe. Release all Emergency Stop buttons.
Summary of Contents for QuickTouch+ 12
Page 10: ...6 QuickTouch Control Station User Manual...
Page 18: ...14 QuickTouch Control Station User Manual...
Page 31: ......