Chapter 2
19
Connect Luminaires to Outputs
CAUTION:
Do not coil excess Category-type cable.
Note:
Use ONE type of output connector. For example, use the RJ45 receptacle OR
the two-pin terminal blocks on a W1 Fade to Warm Driver or a W1 CC Driver.
Navis 100 Luminaires
See the
ArcSystem Navis 100 Installation Guide
for luminaire installation instructions.
ETC documents are available for download in PDF format free of charge at
Navis 100 luminaires can be directly connected to a W1 Driver via Category-type cable in a
daisy chain. Navis 100 Fixed White and Fade to Warm luminaires can also be connected through
a B-Box4 breakout box with RJ45 connectors (FD-BBOX-4R) for installation in star topology.
CAUTION:
Possible damage to equipment. Connect only Navis 100 Fixed
White luminaires to a W1 CC Driver. Connect only Navis 100 Fade to Warm
luminaires to a W1 Fade to Warm Driver. Connect only Navis 100 RGBW
luminaires to a W1 Chroma Driver.
CAUTION:
Possible damage to equipment. Connect only the same types of
luminaires in a wiring run. DO NOT mix Fixed White, Fade to Warm, and
RGBW luminaires in the same wiring run.
Note:
The W1 Chroma Driver ships with an RJ45 DMX terminator. Navis
RGBW luminaires are not self-terminating. You must terminate the last Navis
RGBW luminaire in line with a 120
Ω
resistor.
To purchase extra RJ45 terminators, please contact your ETC customer service
representative and request part number N4086.
Note:
Navis 100 luminaires can be live-plugged into the power/data cable from a W1
Driver while it is powered.
Connect Navis 100 Luminaires in a Daisy Chain
Up to four luminaires can be daisy-chained along one run of cable when using the RJ45 output
from a W1 Driver. The cable distance of the wiring run must not exceed 100 m (328 ft). Refer to
the
ArcSystem Navis 100 Installation Guide
for full details.