Bridge D4 Series Constant Voltage Driver Output Channels
49
Bridge D4 Series Constant Voltage Driver
Output Channels
It is acceptable to bridge multiple output channels together on an ArcSystem D4 Series Constant
Voltage Driver, ganging the maximum output allowed into a single combined output channel.
See below for examples of the configurations made possible by bridging output channels.
Note:
A maximum of two output channels can be bridged together on a D4 Driver
700 (standard or emergency model).
Note:
Do not bridge outputs on a constant current driver. Verify that your driver is an
ArcSystem D4 Series Constant Voltage Driver by looking for one of the following model
numbers on the cover:
•
ARCPD4DCVTM
•
ARCPD4DCVTRDMM
•
ARCD4D350CV24R
•
ARCD4DE350CV24R
•
ARCD4DRDM350CV24R
•
ARCD4DERDM350CV24R
•
ARCD4D350CV24W
•
ARCD4DE350CV24W
•
ARCD4DRMD350CV24W
•
ARCD4DERDM350CV24W
•
ARCD4D700CV24R
•
ARCD4DE700CV24R
•
ARCD4DRDM700CV24R
•
ARCD4DERDM700CV24R
•
ARCD4D700CV24W
•
ARCD4DE700CV24W
•
ARCD4DRDM700CV24W
•
ARCD4DERDM700CV24W
WARNING:
RISK OF DEATH BY ELECTRIC SHOCK! Before you begin pulling
and terminating wire to the ArcSystem Driver enclosure or TX1 Transmitter,
make sure the main circuit breaker cabinet or other readily accessible input
power disconnect device for the normal power input (and emergency power
input when used) is locked out and tagged out.
AVERTISSEMENT :
RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE! Avant
de passer le câblage et de le raccorder au boîtier du driver ArcSystem ou à
l’émetteur TX1, s’assurer de la coupure électrique du disjoncteur principal
ou d'une autre arrivée électrique pour l’alimentation normale (et
l’alimentation de secours lorsqu’elle est utilisée); s’assurer aussi que le
disjoncteur ou le dispositif de déconnexion est verrouillé et identifié.