8
ArcSystem Installation Manual
D1 Series, D2 Series, and D4 Series Drivers
D1 Driver
D1 HO Driver
D2 Driver
D4 Driver
ArcSystem Pro One-Cell luminaires require an external driver. ArcSystem D1, D2, and D4 Series
drivers use standard RJ45 connectors for DMX control.
•
The D1 Driver provides up to 25 W to a single One-Cell or One-Cell Small luminaire.
•
The D1 HO Driver provides up to 100 W to a single One-Cell High Output luminaire.
•
The D2 Driver supports one or two One-Cell Micro luminaires and provides up to 10 W per
output.
•
The D4 Constant Current Driver with Molex connectors supports four One-Cell or One-Cell
Small luminaires.
•
The D4 Constant Current Driver with terminals provides 48 VDC and 400 mA or 600 mA
per output channel, with a maximum total output of 2.4 A or 100 W.
•
The D4 Constant Voltage Driver with terminals provides 24 VDC and up to 50 W per
output channel, with a maximum total output of 2 A or 150 W.
For more information on installation of standard or emergency system drivers, see
System One-Cell Installation on page 14
or
Emergency System One-Cell Installation on page 26
.
Note:
ArcSystem Pro One-Cell Micro and ArcSystem Pro One-Cell standard
luminaires are not interchangeable. One-Cell Micro luminaires require a D2 driver to
function; One-Cell and One-Cell Small luminaires require a D1 driver or D4 driver to
function.
Note:
All ArcSystem wireless luminaires require a TX1 Transmitter and
commissioning tool to set DMX addresses for both wired DMX and wireless
installations. Contact your ETC Service Technician for more information.