ETAS
Technical Data
FETK-T1.1
-
User
Guide
43
7.2.2
Measurement Data Memory
7.2.3
Trace Memory
7.3
Environmental Conditions
Inside the ECU housing the max. temperature is specified with 110
°C, still air.
Outside of the ECU the max. ambient temperature is assumed to be 105
°C at
1
m/s airflow. The power dissipation of the FETK-T1.1 will be max. 5.2 Watt.
Item
Characteristics
Location
Typically located within the emulation
memory when using DISTAB17
hooks. Measurement data memory
can be located in internal RAM if the
entire ED RAM is needed for calibra
-
tion.
Update
Logic devices updated using HSP
software
Item
Characteristics
Trace mirror size
4 MByte (phys.)
Item
Characteristics
Temperature range (operation)
- 40
°C to +110
°C/ - 40
°F to +230
°F
Temperature range (storage)
0
°C to +50
°C/ - 18
°F to +122
°F
Relative humidity (non-condensing)
0 to 95%
Operating altitude
max. 5000 m/ 16400 ft
Contamination level
2
Degree of protection
Determined by installation in ECU
Overvoltage category
(AC mains supply)
II
NOTE
It is recommended to mount the FETK-T1.1 via the heat spreader directly to
the ECU housing.