ES5392.1 High Current Switch Board (6-CH) - User’s Guide
43
ETAS
Connections and Connectors
4.4
Connector X3 Battery Input
The connector X3 Battery Input is used to connect the voltage of the external
power supply.
Counterplug:
Manufacturer: Positronic
Type: D-Sub 3W3, Female
Order number: CBD3W3F0000X/AA (connector)
1xFC4008D/AA (crimp contact)
The pin assignment is as follows:
Tab. 4-3
Connector X3 Battery Input
Shortname
Type
#
PIN
(signal)
PIN
(reference)
Shortname
+VBAT_IN_0*
High current input 0
3
1
-VBAT_IN
+VBAT_IN_1*
High current input 1
2
1
-VBAT_IN
Housing
GND_EARTH
* internally connected
WARNING!
The sum of absolute current values must not exceed 40 A and must
be limited by the upstream element (power supply).
In case on non-observance, overheating can lead to damages to the
ES5392.1, the ES5300 housing and personal injuries.
3
2
1