ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide
9
ETAS
Introduction
1.2.3
Transport and Installation
Please take the following precautionary measures to avoid hardware being dam-
aged by static discharge:
1.2.4
Connecting/Removing Devices
Please take the following precautionary measures to avoid any injuries and dam-
age to hardware:
• Do not apply any voltages to the ports of the ES5371.1 Carrier Board for
ES443x Load Boards which do not correspond to the specifications of the
relevant port.
• Do not connect or disconnect any devices while the ES5300.1-A Housing
or external devices are powered on.
First, power off the ES5300.1-A Housing by shutting down the real-time
PC and using the on/off switch on the back of the device, and detach all
power plugs.
• When inserting any connectors, please make sure they are absolutely
straight and that none of the pins are bent.
1.2.5
Requirements made of the User and Obligations of the Operator
Make sure you only assemble, operate and maintain the product if you have the
relevant qualification for and experience with this product. Incorrect usage or
operation by users without an appropriate qualification can lead to serious or
even fatal injuries as well as damage to property.
General Occupational Health and Safety
The existing regulations on occupational health and safety as well as accident
prevention must be adhered to.
1.2.6
Correct Use
The ES5371.1 Carrier Board for ES443x Load Boards is a plug-in board for the
ES5300 System Housing for accommodating ES443x Load Boards.
The ES5371.1 consists of:
• One slot for holding ES443x boards,
• One SPI and one JTAG interface to the ES5300 System Housing for config-
uring the ES443x board,
• One output interface to the ECU,
• One digital interface for signals to the battery node control,
• One supply voltage of the ES443x board
and
CAUTION!
Some components of the ES5371.1 Carrier Board for ES443x Load
Boards may be damaged or even destroyed by static discharge. Leave
the board in its transport package until you want to install it.
The ES5371.1 Carrier Board for ES443x Load Boards should only be
taken from its package, configured and installed at a working place
that is protected against static discharge.
Summary of Contents for ES5371.1
Page 1: ...ES5371 1 Carrier Board for ES4435 Load Boards User s Guide...
Page 20: ...ES5371 1 Carrier Board for ES443x Load Boards User s Guide 20 Features and Functions ETAS...
Page 30: ...ES5371 1 Carrier Board for ES443x Load Boards User s Guide 30 ETAS Contact Addresses ETAS...