ES5340.2 Electric Drive Simulation Board - User’s Guide
29
ETAS
Installation and Configuration
5. For “CPU Core”, select the core that is to be avail-
able exclusively for this task.
Only cores not used by another task are displayed
here – you may have to release a core (by reconfig-
uring other tasks).
6. Save the project.
To configure measuring in LABCAR-RTC
1. Open the hardware configuration in LABCAR-RTC.
2. Select the item “ES5340-Dig-In-Inverter-Meas”.
3. In the “Globals” tab, select the required settings for
the options “Trigger Mode” and “Nominal PWM
Period Time of Center-Aligned PWM [μsec]”.
4. Toggle to the “Groups” tab.
5. Click the table field in the “Task” column.
6. The “Task selection” window opens.
All “Trigger” tasks for which “Exclusive Core
Usage” has been activated and which are defined in
the OS Configuration of LABCAR-IP are listed here.
Note
The total number of existing processor cores is not
known in LABCAR-IP – only assign cores that are
actually available!