ETAS ES4105.2 User Manual Download Page 4

Contents

4

5

Technical Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

Index  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Summary of Contents for ES4105.2

Page 1: ...ES4105 2 Housing User s Guide...

Page 2: ...or single license Using and copying is only allowed in concurrence with the specifications stip ulated in the contract Under no circumstances may any part of this document be copied repro duced trans...

Page 3: ...lements 7 2 2 Slots 7 2 3 Backplane 7 2 4 Power Supply Unit 7 2 5 Ventilation Fan 7 2 6 Fuses 7 3 Operation 9 3 1 Installation of VMEbus Boards 9 3 2 Removal of VMEbus Boards 9 3 3 Fuse Replacement 10...

Page 4: ...Contents 4 5 Technical Data 15 Index 17...

Page 5: ...for VME boards It has the follow ing features 10 slots standard VMEbus and VME64x boards slots for standard Eurocards 100 mm x 160 mm separated at 4 HP inter vals 22 3 mm 160 pin backplane 3 3 V 5 V...

Page 6: ...Introduction 6...

Page 7: ...xtended VME64x standard boards can be inserted 2 4 Power Supply Unit The power supply unit provides the voltages 3 3 V 5 V 12 V and 12 V The power supply unit is designed as a wide range unit with an...

Page 8: ...Functional Description 8...

Page 9: ...the board is protected by a cover remove this cover 3 Insert the board into the slot Make sure that the top and bottom of the board smoothly slide in the guide rails 4 Push the board in until the con...

Page 10: ...devices connected with the housing by cables have also been powered off 2 Disconnect the power cable of the housing from the rubber socket 3 Unlock the fuse holder in the mains connector with a screw...

Page 11: ...housing back on note If the automatic overcurrent protection cannot be reset check the fuses at the rear of the housing A main fuse is defective if the control lamp in the power switch remains dark e...

Page 12: ...Operation 12...

Page 13: ...12 RsvU 6 GND D05 BG1IN D13 V1 7 MMD D06 BG1OUT D14 V2 8 GND D07 BG2IN D15 RsvU 9 MCTL GND BG2OUT GND GAP 10 GND SYSCLK BG3IN SYSFAIL GA0 11 RESP GND BG3OUT BERR GA1 12 GND DS1 BR0 SysReset 3 3 V 13 R...

Page 14: ...follows Fig 4 1 Connector of Battery Ground 26 GND A05 IRQ5 A12 3 3 V 27 RsvBus A04 IRQ4 A11 LI I 28 GND A03 IRQ3 A10 3 3 V 29 RsvBus A02 IRQ2 A09 LI O 30 GND A01 IRQ1 A08 3 3 V 31 RsvBus 12 V 5 V St...

Page 15: ...Unit Mechanical structure Case with tip up carrying handle Slots 10 slots at 4 HP intervals for standard Eurocards 100 mm x 160 mm Height 4 U 177 2 mm Width 42 HP 22 04 mm 235 4 mm Depth 310 0 mm Out...

Page 16: ...pins 160 per slot Compatibility Standard VMEbus VME64x Termination Passive Battery Ground on the rear of the housing Quantity 1 Mode permanent Air flow free air 84 m3 h Operating temperature 0 C to 70...

Page 17: ...onnectors 13 D Data mechanical 15 technical 15 E Environmental conditions 16 F Fan 16 Features 5 O Operation 9 Output voltage 15 Overcurrent protection 10 P Power supply unit 15 R Removal board 9 Rese...

Page 18: ...Index 18...