Connection to the ECU
For connecting the BR_XETK-S3.0 to the ECU two XETK adapter cables are rec
-
ommended:
• at CON2 adapter ETAM8A or ETAM8B
• at CON3 adapter ETAM2 or ETAM5 or ETAM9 or ETAM10
The adapter cables are to be ordered separately (refer chapter “Ordering Infor
81).
The suitable connectors FCI-20 (CON2) and MOLEX-6 (CON3) should have
been populated onto the ECU PCB for adapters ETAM8 and ETAM2/ ETAM5/
ETAM9/ ETAM10 (see Fig.
2 for additional connector details).
Fig.
5
-
1
BR_XETK-S3.0 Connection to the ECU
CAUTION
Risk of short circuiting the internal signals of the BR_XETK-S3.0!
When you mount the BR_XETK-S3.0 to the ECU, you must ensure that the
screws and washers used will not penetrate the
BR_XETK-S3.0 printed circuit board.
ETAM2 or ETAM5 or ETAM9 or
BR_XETK-S3.0
ETAM8A or ETAM8B
ETAM10