13
Operation PC 20 to 32 kW
2011-12
Maintenance
Overview of activities
"Empty ash box" reminder
"Empty ash box" reminder
The ash box should be emptied regularly. As such,
the factory settings contain a pellet consumption
level at which a reminder to empty the ash box
appears.
If the ash box is only part full after this time, the
value in the "Empty ashbin after" parameter can be
increased. If the value is set to zero, the message
will no longer appear. The fi lling level must then
be checked manually at regular intervals.
Boiler
TUE 4/4/2011 11:25:45
Reminder: check ash box
Counter reset when ash box removed. Empty out ash,
check water pressure and safety valve. See user manual.
Changing the "Empty ashbin after" setting
Press the buttons
and
to go to the text
menu.
Tap the [Boiler] line and, in the submenu, tap the
[Ash removal] line.
Double-tap the [Empty ashbin after] line.
2
x
A settings screen opens:
Enter the new pellet consumption value after
which a reminder will appear to empty the ash
box, then press
to confi rm.
Press the
button to return to the overview.
„Empty ash box“ reminder