ProNet Plus Series AC Servo User's Manual
- 117 -
22
188
754
53
126
754
66
330
754
27
23
196
785
51
131
785
64
344
785
25
24
204
816
49
136
816
61
357
816
24
25
212
848
47
141
848
59
371
848
24
26
220
879
45
147
879
57
385
879
23
27
228
911
44
152
911
55
399
911
22
28
236
942
42
157
942
53
412
942
21
29
243
973
41
162
973
51
426
973
21
30
251
1005
40
168
1005
50
440
1005
20
31
259
1036
39
173
1036
48
454
1036
19
32
267
1068
37
178
1068
47
467
1068
19
33
275
1099
36
183
1099
45
481
1099
18
34
283
1130
35
188
1130
44
495
1130
18
35
291
1162
34
194
1162
43
509
1162
17
36
298
1193
34
199
1193
42
522
1193
17
4.13 Inertia
Overvoltage (A.13) may happen if the servomotorexceeds30 times the load inertiain acceleration
。
Regeneration error (A.16) may happen if using the wrong internal regenerative resistor or external regenerative resistor.
If any of the above alarms happens, take the following actions:
Decrease torque limit value
Decrease deceleration curvature
Decreasehigh speed
If the alarm is not releasedwith the above actions, re-select external regenerative resistor or contact your ESTUN
representative or the dealer from whom you purchased the products.
4.14 Updating Operation
You can fulfill the updating operation by using ESView V3 application, for details see the
ESViewV3 Help
.
Summary of Contents for ProNet Plus Series
Page 1: ...ProNet Plus Series AC Servo User s Manual Version V1 05...
Page 216: ......