E200PS Operation Manual
5
Chapter 2 Operation Example
2.1 Single-Step
2.1.1 Background
Now, There is1 block of metal material, needs to be processed into workpieces with same
length, the require as following:
Length of each workpiece is 100.00mm
Gap is 1.00mm
Distance of retracting is 5.00mm
Time for the backgauge retract waiting is 2.00s
Workpiece is 10.
2.1.2 Analysis
Parameter
Setting
XP
100.00mm
GP
1.00mm
DX
5.00mm
CL
80
PP
10
Others
According to the actual situation to set.
2.1.3 Procedure
Step 1
When the E200PS device is electrified, wait a few seconds into the
SINGLE
page
(Default page).
Step 2
According to the analysis, press the arrow keys and number keys to modify the
corresponding parameters, as shown in Figure 2-1.
SINGLE
:DestPos Of Axis X
Unit:mm
X=
10.00 G =
2.00
XP =
80.00
GP =
1.00
DX =
5.00
CL =
80
PP =
10
CP =
10
XP =
100.00
Figure 2-1
Single-Step example configuration
Step 3
Press
to run the device, the device will enter the running page.