E200P Operation Manual
14
NO.2
PROGRAM
:
X= 10.00 Y = 10.00
ST:
3
STEP
PP:
0
PIECE
CP:
50
PIECE
DLY:
4.00
S
HT:
2.00
S
Figure 3-4
The
PROGRAM
page
The description of the
PROGRAM
parameters is as shown in Figure 3-2.
Table 3-2
The description of the
PROGRAM
parameters
Parameter
Default
Range
Unit
Description
ST
1
0~25
-
The total number of steps in this program.
PP
0
0~99999
-
The number of processing workpiece in this
program.
CP
0
0~99999
-
PP=0: this value is the current work piece.
PP>0: this value is the remain work piece.
DLY
0.00
0~99.99
s
In case of single step, delay time for X-axle
retracting.
HT
0.0
0~99.99
s
The interval time from
LDP
signal to
decompression process.
Step 4
After finishing the setting of the
PROGRAM
page, press
to enter
STEP
page, as
shown in Figure 3-5.
[Operation Guide]:
It automatically makes the step number, according to the value of parameter
ST
on
the
PROGRAM
page.
Please pay attention the sequence of the step, e.g.
1 / 3ST
:
1
indicates the current
step,
3
indicates the total step. The machine will run in sequence.
Press
to enter each step page for editing.
Press
to select the parameter you want to modify, input the value and
press
to finish the operation.
Press
back to
PROGRAM
page.
Summary of Contents for E200P