Page 1: ...SYSTEM INSTALLATIONS UND WARTUNGSANLEITUNG 26 DE SYST M TEPELN HO ERPADLA VZDUCH VODA SERVISN A MONT N MANU L 38 CZ CR LEVEG V Z H SZIVATTY RENDSZER FELSZEREL SI S SZERVIZEL SI K ZIK N 60 HU 72 GR LUF...
Page 2: ...AL REGULATIONS PLEASE LEAVE THIS MANUAL WITH THE UNIT FOR FUTURE REFERENCE TECHNICAL SPECIFICATIONS Rated pressure 1 0 MPa 10 bar Test pressure hydraulic 1 5 MPa 15 bar Minimum recommended supply pres...
Page 3: ...shcaft m b H Petersgasse 45 A 8010 Graz Austria Hungary Magyar AIRCOND Klimaanlagen Handelsgesellshcaft m b H Petersgasse 45 A 8010 Graz Austria Greece Carrier Hellas Aircondilioning S A 4g Andersen s...
Page 4: ...nce 2 0 INSTALLATION GENERAL REQUIREMENTS 2 1 National Wiring Regulations may contain restrictions concerning the installation of these units in certain areas eg Bathrooms 2 2 The unit MUST be install...
Page 5: ...ontinuously downward direction in a frost free environment 3 2 The water connections on the unit accept direct connection of 22mm outside diameter pipe nuts and olives are supplied for this purpose Th...
Page 6: ...t on the front of the cover ISOLATE THE ELECTRICAL SUPPLY BEFORE REMOVING THE COVER 4 3 The cylinder heater MUST be earthed 4 4 All electrical wiring should be carried out by a competent electrician a...
Page 7: ...inder for long periods without draw off will become de oxygenated and potentially corrode the vessel material If the installation is to be left unused following installation and commissioning the wate...
Page 8: ...remove the thermal cut out sensing bulb from its pocket on the cylinder heater by pulling outwards Be careful not to kink the capillary tube 6 6 Remove the element tail insulating shroud by pulling it...
Page 9: ...released 8 0 USER INSTRUCTIONS 8 1 The water storage temperature at the Air to Water Heat Pump System Water Cylinder is set at the control panel of the Hydro Unit This can be set to give temperatures...
Page 10: ...correct parts are ordered 9 2 DO NOT replace with parts not recommended by the manufacturer as this will invalidate your guarantee and may render the installation dangerous 9 3 Description Part No Cy...
Page 11: ...sor 1 Cylinder heater thermal cut out has operated 2 Faulty water cylinder temperature sensor 1 Water storage temperature on Heat Pump Controller is set too high 2 Faulty water cylinder temperature se...
Page 12: ...ervice within a period of 7 days If this is not the case it must either be drained or regularly flushed as required in the section Commissioning Warning 11 7 The unit is NOT guaranteed against damage...
Page 13: ...or the distributor In case of installation of a new product it may be possible to have the distributor pick up old WEEE directly The producer importer and distributor are responsible for collection a...