OPERATOR’S
MANUAL
CMA-9000 FLIGHT MANAGEMENT SYSTEM
Page
3-6
November 19, 2009
CMA-9000 FMS DISPLAY SETUP
From the IDENT 1/2 page, go to DISPLAY 1/1 page, by pressing [INIT REF] and <DISPLAY> (LSK 4L).
1. Press LSK 1L and adjust display PARALLAX for proper viewing angle.
2. Press <DISPLAY> (LSK 3L) and select color or monochrome for this test. Re-select color thereafter.
3. Press <INIT/REF> (LSK 6L).
4. Press <IDENT> (LSK 1L) to return to the IDENT 1/2 page.
1 R
2 R
3 R
4 R
5 R
6 R
DISPLAY 1/1
<
PARALLAX
D I S P L A Y
>
COLOR
<
INIT/REF
1 L
2 L
3 L
4 L
5 L
6 L
This page is printed under user's responsibility