CN2 -
Located on the lower left side of the board, these terminals are outputs for the opera-
tor arm(s), gate locks (optional), and lamps (optional).
APM1, CHM1 - terminals.
For dual operations these ter minals are for the ar m that must
move first, for single operations these terminals are the output for controlling the operator arm.
APM2, CHM2 - terminals.
For dual operations
ONLY.
Connect the ar m that is to move
second to these terminals. For single operations nothing should be connected to these terminals.
ELS - terminals.
Brief 24V output at beginning of operation cycle, meant for release an
electric lock.
LAMP - terminals.
Both a flashing lamp and a courtesy lamp can be connected to these
terminals with a power supply of 24V DC and a max output of 15 W. to change between flash-
ing lamps and courtesy lamps, select parameter “G”.
CN3 -
Located on the center bottom of the board, these terminals are for limit switches.
COMF -
Common ter minal to make the needed normally closed connections for the limit
switches.
FCC1 -
Nor mally closed contact. This ter minal is connected with the COMF through the
limit switch. When tripped (connection opened) it stops the motion of the first operator. (
If not
being used, this terminal must be jumped with COMF)
Master Closed Limit Switch
FCA1 -
Nor mally closed contact. This ter minal is connected with the COMF through the
limit switch. When tripped (connection opened) it stops the motion of the first operator. (
If not
being used, this terminal must be jumped with COMF)
Master Open Limit Switch
FCC2 -
Nor mally closed contact. This ter minal is connected with the COMF through the
limit switch. When tripped (connection opened) it stops the motion of the second operator. (
If
not being used, this terminal must be jumped with COMF)
Slave Closed Limit Switch
FCA2 -
Nor mally closed contact. This ter minal is connected with the COMF through the
limit switch. When tripped (connection opened) it stops the motion of the second operator. (
If
not being used, this terminal must be jumped with COMF)
Slave Open Limit Switch
ENC1, ENC2 - terminals. NOT USED
CN4 -
Located on the bottom right of the board, these terminals are for accessories and safe-
ty devices.
OPEN A - terminal.
This is the most common ter minal for accessories. Accessories utilizing
a normally open contact to set the gate in motion will be attached to this terminal and the COM
terminal (common or also know as ground).
OPEN B - terminal.
This ter minal is for opening the first leaf only in dual gate operations.
It is a normally open contact that must be used in conjunction with the COM terminal.
STOP - terminal.
This is a normally closed ter minal that is used for gate motion stopping
emergency commands.
If a safety device is not being used in this terminal the operator must
have a jumper ran from this terminal to the COM terminal in order to operate.
FSW CL, FSW OP - terminals.
These nor mally closed ter minals are for safety devices dur-
ing the closing (CL) and opening (OP) cycles of the gate.
If a safety device is not being used in
this terminal the operator must have a jumper ran from this terminal to the COM termi-
nal in order to operate.
COM - terminal.
This is a common, or sometimes refer red to as gr ound, ter minal. It is
used in conjunction will
ALL
accessories and safety devices.