20% of total arch
10% of total arch
SOFT
START/
STOP
This parameter determines when the gate will
begin to slow down near the end of opening
and closing cycle.
Low
High
SOFT
SPEED
This parameter determines how fast the gate
will move during the soft start/stop.
If using
positive stops it must be set to 0.
No Limit Switch
Limit Switch
LIMIT
SWITCH
In this parameter you MUST specify whether
you are using limit switches or not for proper
function of your gate.
Single Leaf Gate
Dual Leaf Gate
SINGLE
OR DUAL
In this parameter you MUST specify whether
you are using single gate (one leaf - one
motor) or dual gate (two leaves - two motors).
Press P2 one more time to exit this mode. After
setting your last parameter you must now move
on to programming your gate run times. Pro-
gramming instructions begin on the next page.
Your opener arm(s) will not move prior to
completing gate run time programming.
4.3