3.6
Wiring the Operator Arm(s) for Push To Open
1. Locate the wiring terminal board on the bottom of the
operator arm(s).
2. Wire the operator arms according to the diagram below.
NOTE: 1 indicates Master arm or Single operator connections, 2 indicates Slave arm if ap-
plicable and is not used in single gate installations.
The main difference with Push To Open is the matching of column 1 with column 6 in
the chart above. Note how the FCCs no longer match up and the FCAs don’t either, al-
so the power leads are swapped.
We have recently changed provided wire colors. If your wire colors do not match the
chart above and you need help determining terminal placement, call 1-800-640-GATE
for assistance.
Wiring Connections for Operator Arm Power.
Position
from right
in arm
Color
Inside
Arm
Arm to Board
Wire Color
Terminal
Purpose
Board
Terminal
Block
Board Connection
Terminal
M
Red
Red/White
Lg. Wire
Power
CN2
CHM1 (master)
CHM2 (slave - if dual)
M
Black
Black/White
Lg. Wire
Power
CN2
APM1 (master)
APM2 (slave - if dual)
COM
Yellow Yellow
Sm. Wire
Limit
Common
CN3
COMF (For both master
and slave- if dual)
FCC
Red
Red
Sm. Wire
Limit
Open
Position
CN3
FCA1 (master)
FCA2 (slave - if dual)
FCA
Black
Black
Sm. Wire
Limit
Closed
Position
CN3
FCC1 (master)
FCC2 (slave - if dual)