background image

E-SL 450BD Series Instruction Manual

Estate Swing Summary of Functions 

Estate Slide Summary of Functions 

The Estate Slide is only to be used for vehicular Slide gates in a Class I setting. 

Class  I: 

A vehicular gate opener (or system) intended for use in a home of one-to-four single family 

dwelling, or a garage or parking area associated therewith. 

The Estate Slide automated system was designed and built for controlling vehicle access. Do not use 
for any other purpose. 

The  Estate  Slide  automated  system  automates  residential  Slide-leaf  gates  with  leaves  of up  to  18’  in 
length. 

It consists of a locking electro-mechanical linear operator, powered by a 24V AC transformer, coupled 
with control board that switches the voltage to DC to power the motor. The MASTER card can be pro-
grammed  and  is  used  to  set  the  following:  function  logics,  work  times  (by  self-learning)  and  pause 
times, leaf speed, and the sensitivity of the anti-crushing device. 
The locking system will automatically lock when the motor is not operating. A release system enables 
the gate to be moved by hand in case of a system failure. 

For Your Assistance 

Keep this manual safely stored after installation 

Serial Number ________________________________ 

Date of Purchase _____________________________ 

Place of Purchase ____________________________ 

Have this information on hand while handling all service and warranty issues. 

Summary of Contents for E-SL 450BD Series

Page 1: ...s and stay clear of the system during operation INSTRUCTION MANUAL USER DRIVEN MANUAL Any feedback changes or advice we are glad to hear it Please contact us at support estateswing com E SL 450BD Seri...

Page 2: ...a locking electro mechanical linear operator powered by a 24V AC transformer coupled with control board that switches the voltage to DC to power the motor The MASTER card can be pro grammed and is use...

Page 3: ...rrent Amps 10 Max Run Time 5 6 Minutes Operating Ambient Temperature 4 F to 124 F Motor Rotational Speed 2000r min Gate Leaf Max Length ft Up to 14 Gate Leaf Max Weight lbs Up to 450 Type of Limit Swi...

Page 4: ...terference Important Preliminary Checks To ensure safety and an efficiently operating automated system make sure the following condi tions are observed The gate and post must be suitable for being aut...

Page 5: ...Cement boards for a slab frame and a trowel Low voltage wire will be required to run power to your operator See the power page for specifications If the gate is more than 144 from an a c power supply...

Page 6: ...Operation 4 1 Key release the lever 2 Lift the lever to disengage the gears 3 The motor will not run again until the motor is relocked There is a magnetic sensor that allows the motor to operate be s...

Page 7: ...ach the opener to the base NOTE The gate opener can be placed on the left or right of the driveway The diagram below is for being placed on the left side of the driveway if you are standing on the ins...

Page 8: ...tor from the slab ever has to be adjusted nuts can be inserted just on the threads between the anchor and the bottom of the opener the opener can be moved up the threading and the operator can rest on...

Page 9: ...ke it protrude off the back of the gate more to achieve this Vertical position of gate bracket The hole in the gate bracket should be level with the top of the idler gears when mounted on the gate Aft...

Page 10: ...e belt teeth facing up Repeat gate bracket and belt bracket steps on the other side of the gate to attach the other end of the belt to the gate The belt may need to be cut down to be tight if you gate...

Page 11: ...izontally to match up with the limit magnet The distance between the two should not exceed 1 inch Mount your limit magnet on the provided piece of flat bar The flat bar is intended to be attached to y...

Page 12: ...E SL 450BD Series Instruction Manual Wiring operator 10 magnet magnet...

Page 13: ...board Never plug in the transformer when the wires are not connected to the board Contact between the two lead wires will destroy the transformer Connect the wire not provided from the transformer to...

Page 14: ...ff before changing the setting 1 ON Auto close on the gate will re close from the open position after a time set in the programming sec tion OFF Auto Close off ON Dual gate opener 2 motors OFF Single...

Page 15: ...ET button 6 LED shows P3 Press Push 1 to get P3 setting to 30 7 Press SET button 8 LED shows P4 Press Push 1 to get P4 setting to 3 9 Press SET button 10 LED shows P5 Press Push 1 to get P5 setting to...

Page 16: ...set run time 3 LED shows P3 P3 is the force setting the lower the number the easier the gate will reverse directions when it meets resistance This number may have to be changed to a higher setting if...

Page 17: ...L Control Board 1 Press the Learn Button on the receiver The first press of the learn button will turn the light on The second press will cause the light to blink 2 Press and hold one of the four butt...

Page 18: ...ped mid cycle waiting auto reclose momentary contact will move the gate in the direc tion opposite what it was moving before stopped 4 When open and counting auto reclose pause time momentary contact...

Page 19: ...ontact will have no effect 3 When stopped mid cycle from PUSH 1 or the Receiver momentary contact will open the gate 4 When open with auto reclose on momentary contact will re set pause time and will...

Page 20: ...osed Photocell Photo Input for safety eye photo beam connection normally closed GND Ground for photocell power ground for photo connection V 12VDC Max 100 milliamps for photocell power 24V 24VDC Max 2...

Page 21: ...minals electric lock OP Opening cycle AU Auto reclose countdown CL Closing cycle PH Photo cell disruption If the gate s come in contact with an obstruction the gate s will reverse direction for 2 seco...

Page 22: ...r testing or warranty you will be required to e mail digital photos to the technician This is done in your best interest to save unnecessary shipping expenses and time lost Many times we can come up w...

Page 23: ...gate opener control board 24V Power Negative or GND or PWR of entry device GND terminal of PHOTO block on gate open er control board Push Button Intercoms Normally Open NO or Input INP or Relay of en...

Page 24: ...using a safety device 12V is not a misprint the V terminal has a 12V output Solenoid Gate Lock Positive Lead of lock A terminal of E_LOCK block on gate opener control board Negative Lead of lock B ter...

Reviews: