12
7.2 Limits self-learning
* Functions of Buttons
OPEN:
①
Open the door.
②
To be set to normally open mode after being
pressed and hold for 3 seconds .
③
Increase parameter value during
setting.
CLOSE:
①
Close the door.
②
Restore automatic close function after being
pressed in normally open mode.
③
Decrease parameter value during
setting.
STOP:
①
Stop the running door.
②
Exit from setting.
SET:
①
Enter SETTING after being pressed and hold for 3 seconds.
②
Switch menu when entering setting.
③
Exit the setting by keep pressing.
The Opener can be used only after the Limits Self-learning (setting) is
nished.
Close the doors completely before power on.When the display value of the
digital tube changes from 40 to 10, it means that the limits setting is completed.
If the door open after power-on,dial the dip-switch 3 to the opposite , then
power off and power on again.
7.3 Transmitter's coding and Erasing
7.3.1 Transmitter's code setting
Press "LEARN”button on the Control Board to the LED light on, then press the
button which you choose on the transmitter till the LED
ashes and goes out.
Now, the transmitter is coded. Other transmitters can be coded as this way.
7.3.2 Erasing the transmitter's code
Press" LEARN”button on the Control Board and hold on to make the "LEARN
LED" light on up to go out. Now, all transmitters which had been coded are
cleared.