10
Disinfecting Base
1. Pour 1/2 gallon (1.89 litres) of water and 1/2 teaspoon (2.5 millilitres) chlorine
bleach into the base. Let solution stay for 20 minutes, carefully swishing every
few minutes. Wet all surfaces normally exposed to water.
2. Empty base after 20 minutes. Rinse with water until bleach smell is gone.
Allow unit to dry out completely.
NOTE:
The water bottle should be cleaned in the same manner as the base.
Rinse thoroughly with clean water after all steps are complete
End of Season Maintenance
1.
Follow “Bi-Weekly Maintenance” instructions at end of humidification season.
2. Remove filter.
3. Let humidifier dry completely before storing.
4. Store in cool, dry location.
5. Install a new filter in clean humidifier before next season begins.
NOTE:
“Bi-Weekly Maintenance” procedure is also recommended if you do not
plan to run the humidifier for one week or more.
Troubleshooting
Trouble
Probable Cause
Remedy
Digital display not
illuminated.
• No Power.
• Power button has not been
depressed.
• Check 120 volt power
source.
• Press power button once to
turn on.
Fan not operating (digital
display is illuminated).
•
ROOM
humidity level is not
3% or more below
SET
humidity level.
• Reservoir is empty.
• Raise
SET
humidity level if
desired.
• Increase fan speed.
• Fill humidifier with water.
Fan running
continuously.
•
SET
humidity level is 65%.
•
ROOM
humidity level has
not reached 1% or more
above
SET
humidity level.
• A
SET
humidity percentage
of 65% operates fan
continuously. Adjust
SET
level between 25% - 60%.
• Continue to run until
desired humidity level is
achieved. This may take
up to 48 hours initially.
Poor evaporation of
water.
•
CHECK FILTER
(CF)
message flashing.
• Mineral buildup on filter.
• Change to a fresh new
filter.
• NOTE: Local water varies
from area to area and
under certain conditions
minerals will build up more
rapidly in the filter.
Bottle empties
completely
• This is normal for initial
filling
• Refill bottle for maximum
run time.
Bottle continues to empty
after complete filling.
• Air is entering water bottle.
• Check for leak in water
bottle.
• Ensure fill valve position is
turned to closed and valve
has no interfering debris.