Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons 
cannot  restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified 
electrician.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
Always use the correct type and wattage bulb.  Never exceed the wattage stated.
When changing a bulb, always switch off at the mains and allow the old bulb to cool down before handling.  Dispose 
of used bulbs carefully and responsibly.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. 
Check with your local authority or retailer for recycling advice.
This product is rated at IP44.
This  product is not suitable for location in or near a marine environment.
The entire unit gets hot whilst on for a period of time.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

Max 42W E27 GLS

Lumens: 550lm
IP rating: 

44

PIR load: 

Max 100W

Having correctly identified the wiring from your light fitting, connect to the terminal block in the following way:

Wiring

Installation

Existing fittings must be completely removed before installation of a 
new product. Before removing the existing fitting, carefully note the 
position of each set of wires
.

•  Remove mounting box (A) from product by removing dome nuts 

(C) and washers (D). Carefully pierce a small hole in the rubber 
gasket in the centre of the mounting box to allow the cable to pass 
through.

•  Thread the cable through the hole, ensuring the drain hole is at the 

base of the mounting box.

•  Use the mounting box as a template to mark and drill the holes in 

the correct position.

•  Fix the mounting box to the wall using the screws and plugs 

supplied (B). Ensure the wall is capable of holding the weight of 
the product. Take care to avoid damaging any concealed wiring and 
pipes. The correct fixings should be used for brick or cavity walls.

•  Seal the screw fixings to maintain the IP rating of the fitting.

Check that...

•  You have correctly identified the 

wires.

•  The connections are tight.
•  No loose strands have been left out 

of the connection block.

NEUTRAL 

EARTH

SWITCHED LIVE

 

BLUE (N) 

BROWN (L)

GREEN/YELLOW

SUPPLY

LIGHT FITTING

•  Ensure that the cable is not snagged and seal the entry to maintain the IP rating of the product.
•  Fit the product back on to the mounting box and refit washers (D) and dome nuts (C), tighten dome nuts to secure.
•  Replace fuse or circuit breaker and switch on. Your light is now ready for use. 

Commissioning

PIR Adjustment

•  The unit must be installed in a vertical position, and fitted 1.8m above the ground.
•  The PIR sensor can be adjusted, allowing the detection distance to be altered to suit the location. The detection 

angle is set at 120 degrees. The duration that the lamp stays on can also be altered from 5 seconds - 8 minutes. 
Use a small screwdriver to adjust the ‘TIME’ and ‘SENS’ screws. When adjusting the sensitivity (detection 
distance) in daylight it will be necessary to cover the sensor to simulate night time.