Page 1: ...15 01 2019 Alarm system for elevators compliant with the European Standard EN 81 28 2018 HELPY 2W TL QUICK GUIDE...

Page 2: ...12 V 12 V power supply Helpy 2W TL A Internal power supply connector B Built in backup battery connector C Reset pushbutton D Alarm pushbutton E Serial port for PC connection F Built in loudspeaker c...

Page 3: ...A Reset pushbutton B Alarm pushbutton C Serial port for PC connection D Built in loudspeaker connector E RJ11 connector for local telephone F Jumper J16 for define the behaviour of output AI Jumper J...

Page 4: ...ut 3 1 AL2 Alarm input 4 2 Auxiliary input 4 Reset input 4 IN1 Alarm 1 filter input 3 Reset input 4 ALT2 Output for connecting the loudspeaker of passive speaker units MIC2 Input for connecting the mi...

Page 5: ...e if present from the A connector in the picture at page 2 2 can be connected to a block to the block 12 or to an external reference 3 allows to connect voltage free contact pushbuttons NO or NC or po...

Page 6: ...minal indicated by to a ground socket in order to increase the telephone line protection Connect the telephone line to terminal LTI GSM200 C module Please see also the GSM200 C User Manual Connect the...

Page 7: ...The passive speaker unit can be installed at max 6 m distance from Helpy 2W TL or from 2W speaker unit by using a shielded cable Each 2W speaker unit connected over the bus the built in speaker unit...

Page 8: ...er supply input 12 Vdc Negative AR Received alarm indicator light light positive pole AI Given alarm indicator light light positive pole AR Received alarm indicator light light negative pole AI Given...

Page 9: ...ing the microphone of a passive speaker unit or a single microphone Negative H Microphone DIP switch The DIP switch allows to assign an ID 01 16 to each 2W speaker unit connected to the bus Note it is...

Page 10: ...L BUTTONS Car pushbutton It is possible to connect inside the elevator car voltage free contact pushbuttons or powered pushbuttons Connect following one of the diagrams shown below the car pushbutton...

Page 11: ...e contact pushbuttons NO or NC Connect following the diagram shown below the external pushbutton 2W speaker unit pushbuttons It is possible to connect external pushbuttons voltage free contact pushbut...

Page 12: ...Page 12 CONNECTING THE EMERGENCY CALL BUTTONS this solution is allowed only if the negative pole of Helpy 2W TL is not connected to the negative pole of the lift...

Page 13: ...TING THE FILTER INPUT Connect following one of the diagrams shown below the filter contact Note if a 2W speaker unit is installed in the cabin it is possible to use the terminal block s filter input o...

Page 14: ...INDICATOR LIGHT yellow switches on after pressing the emergency button to indicate the beginning of the alarm procedure The RECEIVED ALARM INDICATOR LIGHT green switches on when the alarm call is answ...

Page 15: ...er unit indicator lights Some 2W speaker unit models come with built in indicator lights It is also possible to connect external indicator lights Connect following one of the diagrams shown below the...

Page 16: ...Y Connect the output RL1 normally open contact to the external device CONNECTING THE AUXILIARY INPUTS Helpy 2W TL It is possible to configure the AL2 input of Helpy 2W TL as auxiliary input normally o...

Page 17: ...WIRING DIAGRAMS Page 17 WIRING DIAGRAMS WIRING DIAGRAM WITH 2W SPEAKER UNIT IN THE PIT...

Page 18: ...Page 18 WIRING DIAGRAMS WIRING DIAGRAM WITH PASSIVE SPEAKER UNIT IN THE ELEVATOR CAR BOTTOM...

Page 19: ...WIRING DIAGRAMS Page 19 WIRING DIAGRAM WITH LANDING FLOORS...

Page 20: ...hang up To listen again to the previous message lift the handset and dial Make an external call to check the GSM200 C module is properly working dial and after the Correct message digit the telephone...

Page 21: ...son 4 RESETTING THE ALARM Note the alarm reset mode can be configured with the Alarm reset mode programming code 77 1st mode reset by End code factory default Press to end the alarm 2nd mode automatic...

Page 22: ...set parameters Use of the reset pushbutton C in the picture at page 2 A in the picture at page 3 Pressing shortly Allows to interrupt an alarm call By pressing shortly you get the same result as lifti...

Page 23: ...factory default EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD factory default TELEPHONE NUMBERS INST the programming of the telephone number automatically activates the alarm call only with...

Page 24: ...T WEEKDAY dd mm yy SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY TIME INST hhmm from 0000 to 2359 RECORD MESSAGES INST identification message max 25s record hang up courtesy message max 25...

Page 25: ...alarm automatic test disabled automatic test enabled EN 81 28 2018 automatic test enabled EN 81 28 2004 Make a test call manually PROTOCOLS IDENTIFICATION CODE INST Esse ti identification code P100 S...

Page 26: ...NORMALLY OPEN CLOSED INST AL1 0 normally closed 1 normally open AL2 0 normally closed 1 normally open HELPY 2W TL INPUTS SETTING INST AL2 alarm input IN1 filter input AL2 auxiliary input IN1 filter i...

Page 27: ...rm factory default 11 FILTER ACTIVATION INST OPER disabled enabled FILTER INPUT NORMALLY CLOSED OPEN INST OPER normally closed normally open FILTER BYPASS INST seconds from 15 to 30 ALARM OPERATION WI...

Page 28: ...message courtesy message LANGUAGE INST language 00 Italian 01 English 02 German 03 French 04 Polish 05 Portuguese 06 Russian 07 Spanish MULTI LANGUAGE COURTESY MESSAGE INST second language third lang...

Page 29: ...t 2 OPERATION MODE AFTER AUTOMATIC ANSWER INST programming mode direct connection with the car CONNECTION DURATION AFTER AUTOMATIC RESPONSE INST minutes from 1 to 9 CLI CALL DURATION CLI seconds from...

Page 30: ...EL INST Digits Quality 0 12 no signal or connection not guaranteed 13 18 low signal 19 24 medium signal 24 high signal ENTER SIM CARD PIN CODE with GSM200 C INST PIN PIN DISABLE SIM CARD PIN REQUEST w...

Page 31: ...essages of the Helpy 2W TL set a micro SD card to use for programming customizing the messages and updating the firmware of the Helpy 2W TL e stant can be downloaded at the following link https www es...

Page 32: ...assword which allows access to programming and the programming codes to be performed The message format must be as follows Et he xxx c c c c Where Et he is the start of the programming string xxx is t...

Page 33: ...NVERSATION WITH THE SPEAKER UNITS CABIN SPEAKER UNIT ID 01 SPEAKER UNIT ID 02 SPEAKER UNIT ID 03 SPEAKER UNIT ID XX 04 16 DEACTIVATE ALL EXTERNAL CALLS TELEPHONE NUMBER DOOR OPENER RELAY Use remotely...

Page 34: ...of the programming and functions below can now be performed USE REMOTELY WITH HELPY 2W TL AT REST PROGRAMMING CONVERSATION WITH THE SPEAKER UNITS CABIN SPEAKER UNIT ID 01 SPEAKER UNIT ID 02 SPEAKER U...

Page 35: ...alarm periodical test call yellow Emergency call alarm Emergency call alarm suspended Other alarms Test call LED signalling GSM200 C signal strength green No signal Low signal level Medium signal lev...

Page 36: ...g device status red Normal operation no alarm Alarm Voice connection Battery disconnected or low battery max 1 hour operation in idle state 2W speaker unit connection error or bus problem Absence of t...

Page 37: ...the battery has low capacity charge The external power supply is connected and the battery is either disconnected or dead The external power supply is disconnected and the battery guarantees more tha...

Page 38: ...Missed test call notification The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call The flashing sequence ends a...

Page 39: ...text of the EU declaration of conformity is available from the following Internet address https www esse ti it en dichiarazioni di conformita Information to be provided with the lift The information E...

Page 40: ...Esse ti S r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it support esse ti it...