Espa SILEN ST Instruction Manual Download Page 1

 

RPM4 pressure monitor,    
Fan replacement instructions 

See the RPM4 Operators Manual for more information on the operation and use of the RPM4 pressure 
monitor 

Part Number: 3140519 
Description: 103282,FAN,12V,25X25X100,1.3CFM 
 

1.

 

Remove the feet from the RPM4  
 

2.

 

Remove the enclosure from the RPM4. Don't let the front panel fall on its face when removing the enclosure 
 

3.

 

Remove the Q-RPT module(s) by removing the four screws on the back panel that hold them in 
 

4.

 

Loosen the screws (don’t remove them) that hold the electronic chassis (power supply, driver board, micro-board and 
barometer) to the bottom enclosure panel 
 

 

 

5.

 

Slide the electronic chassis out of the retaining rails to access and replace the fan 
 

6.

 

If you loosen the screws too much, attach the mounting nuts back onto the M3x5 screws and washers. Turn the 
chassis upside down to hold the lock washers on the screws if you have to. Leave the screws loose 
 

 