1. Introduction

Dear Costumer, 
Thank you for purchasing the solar light. With this solar light you purchased a product
manufactured according to the current state of technology. 

This product fulfils all requirements of the valid European and national regula-
tions. The conformity was proved. The relevant declarations and documentati-
on are deposited with the manufacturer. 

To maintain this state and guarantee a safe operation, you as the user will have to fol-
low this operating manual!

2. Safety Instructions

- In case of damages caused by not 

following this operating manual, the 
warranty rights will expire! We exclude 

liability for any consequential damages!

- We exclude liability for property or 

personal damages caused by inappropriate 
handling or not following the safety instructions. 

- In these cases any guarantee rights will expire.

Due to safety and admission reasons (CE) it is not allowed to arbitrarily reconstruct
and/or change the solar light. 
Therefore, please keep to the operating manual. 
The  accident  prevention  rules  of  the  association  of  the  industrial  trade  cooperative
association for electric plants and working material are to be considered in industrial
environments.

3. Intended use

This submersible pump is designed for pumping water in garden ponds, fountains,
water dishes, etc.  It can pump water through a hose connection or can be operated
through attached lifting tubes with water sprinklers. 
A solar module or a power pack with a voltage of 12 to 24 volts can be used as the
energy source. When used with a solar module, the pump works only if enough
solar radiation strikes the solar module. 
A battery box (accessory) is delivered along with this pump. When battery is on, an
LED light (accessory) can be attached to the lifting tube. This gives the fountain a
decorative lighting. The LED light rings are available in different colours.
The delivery rate of the pump can be adjusted using the regulator on the front side
of the pump. The water pump has no On/Off switch. As soon as the pump is con-
nected to its power supply, it starts pumping water. 

4. Installation and commissioning

1.  Roll out the connecting cable of the

pump completely. 

2. Ensure that the cap is firmly in place on

the socket. 

3.  Place the pump in water (please note

Point 5 here).

4.  Connect the lifting tubes till they project

out of the water surface. For this, first
attach the reducer to the pump.

5. You can now choose from 2 different

water nozzles.

6. Alternatively, the pump can also be used

for pumping water through a hose.  For
this, you just have to attach a hose to the
pump’s pipe. 

7. Now supply power to the water pump

through a solar module. Use the enclo-
sed plug with cable (brown = positive
pole, blue = negative pole) for this. If you
have purchased this pump as a complete
solar power system, then the appropriate
plug is already attached to the solar module. 

Note: 

The plug has reverse-polarity protection, no force should be used while inser-

ting. The glass of the solar module is fragile. 
Caution! Risk of injury!  A broken module cannot be repaired again and must be dis-
posed off in an environmental-friendly way. 

8.  If the pumping capacity is too high, you can reduce the amount of water. Simply

turn the regulator on the front side of the pump in clockwise direction.  Please
do not use force while adjusting. The adjustment range is 45°. 

4.1 Operation with LED light ring

The accessories include a LED light ring. This light ring can be easily slipped onto
the lifting tube. 
Electrical connection is established via the socket on the pump. For this, remove
the drain plug, insert the light ring plug in the socket and tighten the cap nut firmly.
Depending on the model, the lighting is activated/switched-on immediately or via a
twilight sensor.

5. Dry run protection

The pump is equipped as standard with a dry run protec-
tion. Two sensor points are provided on the side of the
housing  for  this.  The  pump  works  if  these  points  are
under water. If a point projects out of the water, the pump
does not work.

6. Care and maintenance 

For  optimum  performance  of  the  pump,  it  must  be  washed  occasionally  with  warm
water depending on the water contamination. To wash the pump, open the housing
as follows:

Note: 

Please do not use force while dismantling or assembling the pump. The parts

are very fragile and can break easily. 

1. Disconnect the pump’s plug. 
2.  Pull the front cover of the pump forward like a slide gently (Figure 1).  
3.  Turn the front cover of the pump by about 45° clockwise (Figure 1) and carefully

pull the cover forward (Figure 2).  Watch out for the plastic shaft and the seal while
doing this.

4.  Carefully drag the impeller out of the pump (if necessary, use pliers).  (Figure 3). 
5.  Now clean all the parts carefully with warm water.  
6.  Then plug the shaft with the impeller carefully into the hole of the pump. Ensure

that the shaft is fitted firmly.

7.  Now place the cover carefully over the pump. Ensure that the seal is fitted proper-

ly. 

8.  Turn the front cover again by 45 degrees counter-clockwise into the starting posi-

tion. 

9.  Slide the lower part of the pump completely into the pump housing. 

The pump is ready to use again.

7. Malfunction

Pump is not pumping water

- Is the pump completely submerged in water? Dry run protection (Point 5)
- Is the polarity of the supply voltage reversed?  Cable colour brown = + pole, 

blue = negative pole

- Is the pump dirty? Cleaning the pump, see Point 6.

8. Technical data

Operating voltage:

12 - 24 V DC

Degree of protection:      IP 68
Power consumption: 

Approx. 3 W at 12 VDC - approx. 12 W at 24 VDC

Pump lift:

Max. 0.8 m at 12 VDC - max. 2 m at 24 VDC

Delivery rate: 

Max. 470 l/h at 12 VDC - max. 750 l/h at 24 VDC

Operating temp. range:  +4 to +40°C

Note:

The pump is only suitable for pumping water. 

Note:

Protect the pump from frost! 

During  cold  winter  months,  the  pump  must  be  taken  out  of  the  water  and
placed/stored in a warm area. The solar module can spend the winter outdoors. 

!

GB

Sensorpoints

lifting tubes

water nozzle

water nozzle

lifting tubes

turn 45°

1

2

3

Customer support:

If you have problems or questions regarding this product, simply contact us!  

Monday to Friday 8 am to 12 noon and 1 pm to 4 pm.

By phone: 09605-92206-27
By e-mail for ordering spare parts: 

[email protected]

By e-mail for questions about the product: 

[email protected]

Product: Manufacturer Item No.: 101757

Drain plug

Light ring
connection

Reviews: