10
Kongsberg XP
Note:
iPC 2.1
: The mechanism of compensating Z height during cutting, based on table top mapping, has
been disabled when cutting underlay has been measured to be more than 5mm.
This level is normally reached when milling on top of milling mat and conveyor belt.
This exception was introduced long time ago, before using conveyor belts.
At that time, a (MDF) plate was used as milling underlay. The plate was milled in order to make a
perfectly compensated underlay for milling.
As this function is not used anymore, and conveyor belts break the 5 mm limit, iPC now always
compensate based on table top mapping.
A registry setting is available to enable the old behavior.
10.8. Calibrate Foot on Measuring Station
Machine Connection
->
Machine Configuration
->
Installation
_>
Calibrate Measuring Pad
Use this wizard to calibrate the height level of the
Measuring Station
.
Typical use is after maintenance or repair; to ensure the tool height measuring system works properly.
Procedure:
1.
Press the
Calibrate Foot
.
2.
Follow the instruction given by the wizard.
3.
Repeat this procedure after maintenance on the
Traverse
,
Carriage
or
Measuring Station
.
10.9.
Reference Points
and
Coordinate System
Reference Points
settings is maintained from:
Menu Bar
->
Edit
->
Options
...->
Reference Points
All X and Y coordinates in the
Input File
have the selected
Reference Point
as origin.
Two modes of operation are available:
• Using
Main Reference Point
• Using
User Defined Reference Point
56