esera automation Shutter Pro V4 User Manual Download Page 1

 

 
 

Art. No. 11231  

 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11231 V2.0 R1.0  Manual 

Page 1 of 7 

User Guide 

Shutter Pro V4 

for external roller shutters, awnings, 

blinds or venetian blinds 

and 1-Wire bus system 

 

 
 
Operation purpose / area of operation:  

  Control of shutters, awnings, blinds or venetian blinds by 

control or manual operation

 

 

Control of heating mixers 

 

 
Equipment: 

 

 

Standard 1-Wire interface and control input 

   Push-button interface for external DC voltage 

   Manual control via push-button 

   Control of powerful tubular motors through  

 robust module design   

   Automatic safety switch-off of the motor 

   LED display for up or down operation 

   DIN rail housing for control cabinet installation  

   screw terminal connection 

   New, with DS2408 interface 

 

 

Introduction 

Before you start assembling the Shutter Pro V4 and put the device into operation, please read this assembly and 
operating instructions carefully to the end, especially the section referring to the safety notes. 
 

Product description 

With the Shutter Pro a motor or motor group* for external roller shutters, awnings, blinds or venetian blinds can 
easily be controlled. An operation in combination with a heating mixer is also possible. 
The Shutter Pro has three interfaces for control. Manual operation via push-button on the module surface, control 
inputs for manual operation and the 1-Wire data interface.  
The combination of the interfaces makes central and convenient automatic control as well as local decentralised 
control possible. All three interfaces can be operated in parallel.  
The roller shutter can be operated manually or automatic operation can be stopped at any time by means of 
external up/down buttons, which are mounted in the area of the window, for example. 
An external DC voltage in the range of 10-30V is used for the operation of the push-buttons. 
The Shutter Pro has two modes of operation, which can be divided into the functions of the module push-buttons, 
Up/Down and the external interface (push-button interface). The difference is that in this operating mode an 
additional push-button function is available for tilting the external blinds (see table Push-button function, no. 6). 
An integrated safety function automatically switches off the connected motor after 120 seconds. 
If the running direction changes (up/down), a pause is automatically maintained to protect the mechanics of the 
tubular motors and roller blinds. 
All internal functions are controlled and monitored by a modern microcontroller. 

 

*

The use of one isolating relay per tubular motor is necessary to control roller shutter groups. 

Summary of Contents for Shutter Pro V4

Page 1: ...tian blinds can easily be controlled An operation in combination with a heating mixer is also possible The Shutter Pro has three interfaces for control Manual operation via push button on the module surface control inputs for manual operation and the 1 Wire data interface The combination of the interfaces makes central and convenient automatic control as well as local decentralised control possibl...

Page 2: ...nds Control input function 1 roller shutter or awning operation control inputs for upwards stop downwards 2 external blinds or venetian blinds button short for tilting movement button long for upwards movement Stop Down During motor operation the control inputs and module buttons can be used to stop the movement Control inputs Digital binary input 10 30VDC max 10mA pulse duration min 40ms e g for ...

Page 3: ... a dual function motor control Switching the operating mode 1 blind operation with tilting function 2 shutter operation Shutter operation pushbutton start motor upwards Blinds operation short pushbutton action Tilting movement for blind motor Up Down long pushbutton action Start motor movement Up Down Manual operation Down module topside DOWN Up external clamp 5 Push button input shutter up Roller...

Page 4: ...ctions after approx 120 seconds by switching off the safety motor Within the Shutter Pro module a microcontroller takes over the management of the manual operation all interfaces and the control of the relays incl pause function and safety shutdown The relays are electronically connected in such a way that upward and downward operation is never switched simultaneously The query of the external int...

Page 5: ...s 500 set owd sht 2 1 500 OWD Number 2 is switched to DOWN for 500ms 750 Milliseconds ms 750 set owd sht 2 1 250 OWD Number 2 is switched to DOWN for 750ms 1 bis 60 seconds 1 60 set owd sht 2 1 34 OWD Number 2 is set to DOWN for 34 seconds The Shutter Pro makes a stop after the run time This switches off the outputs and stops the shutter After switching the output the new state is output as confir...

Page 6: ... vapours or dust are present or may be present 14 Assembly The installation site must be protected from moisture The device may only be used in dry indoor rooms and in protected outdoor areas The device is intended for installation inside a control cabinet as a stationary device 15 Disposal Note Do not dispose of the device in domestic waste Electronic devices must be disposed of at the local coll...

Page 7: ...ime of transfer of risk to be free from material and workmanship defects and have the contractually assured characteristics The statutory warranty period of two years begins from date of invoice The warranty does not extend to the normal operational wear and normal wear and tear Customer claims for damages for example for non performance fault in contracting breach of secondary contractual obligat...

Reviews: