MS 100 Multisensor 

Temperature, Humidity and Brightness 

for 1-Wire Bus system 

 
 

 

 

High-quality Multisensor for temperature 
and rel. humidity with 12 Bit resolution 

 

Light sensor for detection of ambient 
brightness 

 

Voltage monitoring integrated 

 

Equipped with original DS2438 chip 

 

Mounting on flush-mounted boxes 
possible 

 

Universal surface mounting 

 

Shapely and high quality sensor housing 
with integrated ventilation slots 

 

Connection via screw terminals 

 

Simple power supply (5V 

 
 
 

Application 

 

Temperature sensor for individual room 
control  

 

Control sensor for ventilation system 

 

Monitoring of living spaces for mold risk 

 
 
 

 
 
 

 

 

Note 

Before you start assembling the device and put it into operation, read these operating instructions 
through to the end, especially the section on safety instructions.   

Summary of Contents for MS 100

Page 1: ... 12 Bit resolution Light sensor for detection of ambient brightness Voltage monitoring integrated Equipped with original DS2438 chip Mounting on flush mounted boxes possible Universal surface mounting Shapely and high quality sensor housing with integrated ventilation slots Connection via screw terminals Simple power supply 5V Application Temperature sensor for individual room control Control sens...

Page 2: ...ble from the ESERA website Calibration of the internal sensors is not necessary The device can be put into operation immediately without waiting time The electrical connection to the 1 Wire Bus system of the MS 100 is done with screw terminals and can be operated in standard mode with 3 cables for ground data and 5V Each MS 100 Multisensor has an individual serial number The Multisensor contains a...

Page 3: ...arasitic mode is not supported MS 100 Multisensor Note The module may only be operated at the voltages and under the ambient conditions specified for it The modules may only be commissioned by a qualified electrician Please observe the specified operating position of the device For further information on the operating conditions see the following instructions under Operating conditions Due to the ...

Page 4: ...et brightness Lux example 800 00 Lux For further information on the options and commands please refer to the current Programming Manual of the 1 Wire Controller 1 Wire Gateway which can be found within Config Tool 3 8 Integration in IP Symcon For the integration of the 1 Wire Controllers a suitable ESERA module for all sensors and controllers is available in the IP Symcon module store This can be ...

Page 5: ...nated as 1 Wire Bus load Each increase in a factor increases the total 1 Wire Bus load for the 1 Wire Controller and thus reduces the maximum network size According to our many years of experience and a lot of feedback from customers the following conservative recommendation can be made Maximum cable length 50 120m Number of 1 Wire devices no more than 20 22 pieces As linear a topology as possible...

Page 6: ...blies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged Live cables or wires to which the device or an assembly is connected must always be tested for insulation faults or breaks If an error is detected in the supply line the device must be immediately taken out of operation until the fa...

Page 7: ...ch ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We develop our products further and we re...

Reviews: