11601-24  V1.0 R1.1  Manual 

Page 1 of 13 

 

 

User Guide 

 

ECO 10 1-Wire Controller 

 

Professional 1-Wire Controller 

of the 3rd Generation 

 

 

 

  The ECO 10 1-Wire Controller represents a high-

performance 3rd generation 1-Wire Interface for 
sensors and actuators 

  Fully automatic integration of sensors* and 

actuators* 

  Auto-E-Connect Support Level I and II 

  1-Wire Controller for autonomous communication 

and updating of the 1-Wire Network.  

  Fast readout of all 1-Wire Components in a  

1-2 seconds cycle  

  Cyclic output of the processed 1-Wire data in plain 

text 

  Data communication via socket server/client, TCP 

or UDP 

  Designed for small to large 1-Wire Networks 

  Power supply of the 1-Wire Network 

  Top-hat rail housing for control cabinet installation  

  Wide supply voltage range 

  Management of all ESERA and many standard  

1-Wire Modules and Chips 

   

 
 
 
 
 
 
 

 

Note 

Before you start assembling the ECO 10 and put the unit into operation, read this operating manual 
thoroughly, especially the section on safety instructions.  
All settings and configurations of the ECO 10 are carried out with the Config Tool 3 software.  
You can find this software on the ESERA website. Please refer to the operating instructions for Config 
Tool 3, which you will find under the "HELP/SUPPORT" tab within the Config Tool 3 software. 
 

Summary of Contents for ECO 10

Page 1: ...e Controller for autonomous communication and updating of the 1 Wire Network Fast readout of all 1 Wire Components in a 1 2 seconds cycle Cyclic output of the processed 1 Wire data in plain text Data communication via socket server client TCP or UDP Designed for small to large 1 Wire Networks Power supply of the 1 Wire Network Top hat rail housing for control cabinet installation Wide supply volta...

Page 2: ...outputs the adapted data in plain text adapted to the scanned 1 Wire Devices Designed for all 1 Wire Networks The 1 Wire interface of the ECO 10 is specially designed to safely operate small to very large 1 Wire Networks with long cable distances 1 Wire Devices can be operated simultaneously in parasitic or normal mode The currently strongest 1 Wire interface has been developed for maximum data se...

Page 3: ... started and ready formatted data is output The Auto E Connect functionality will be available for the ECO Controller and ESERA Station 200 Pro from 2021 Auto E Connect Level I OWD Detect detection of new sensors and actuators and automatic start of adapted libraries Auto E Connect Level II Visualisation product data read out and visualise the Auto E Connect and manufacturer data of sensors and ac...

Page 4: ... 2 5qmm cable cross section Output voltage 5V 10 max 300mA overload overvoltage and short circuit protected Isolation Galvanic isolation between Ethernet and 1 Wire interface Supported DS2401 DS1963 DS1990 DS1820 DS18S20 DS18B20 DS2413 DS2438 DS2450 1 Wire Devices DS2408 DS2405 DS2406 input only DS2423 other chips on request We will be happy to support further components as an OEM product for you ...

Page 5: ... Reset Button Operating the reset button with non conductive material e g match The reset is carried out via the reset button of the system carried out When the button is pressed the unit is restarted The stored data is retained but all connections are interrupted This keystroke does not correspond to an interruption of the power supply Note The Minus pole of the supply voltage power supply unit o...

Page 6: ...eserved Reproduction as well as electronic duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH 2021 www esera de 11601 24 V1 0 R1 1 Manual Page 6 of 13 10 Connection example 1 Wire Multisensor 11 Connection example only iButton reading unit ...

Page 7: ... actuator All rights reserved Reproduction as well as electronic duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH 2021 www esera de 11601 24 V1 0 R1 1 Manual Page 7 of 13 12 Connection example with iButton and or RFID reading unit ...

Page 8: ...or All rights reserved Reproduction as well as electronic duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH 2021 www esera de 11601 24 V1 0 R1 1 Manual Page 8 of 13 13 Connection example 1 Wire Hub III sensors and actuators ...

Page 9: ...perated with the ESERA Config Tool 3 Since communication between ECO 10 and Config Tool 3 takes place via the open ESERA ASCII text protocol you can also exchange data with any terminal program e g z B Hercules oder Putty via UDP TCP IP at any time with ECO 10 and carry out the configuration Details on the communication commands can be found in the document Programming Manual which can be found in...

Page 10: ...ation can be made Maximum cable length 50 120m Number of 1 Wire devices no more than 20 22 pieces As linear a topology as possible without T junctions The topology in particular plays a major role If possible it should be installed in a linear topology The linear topology can be compared like pearls on a pearl necklace The data line should be laid from one device to the next without T joints Furth...

Page 11: ...ion in Loxone Via the shop we provide a sample project for the simple integration of the ECO 10 into the Loxone Miniserver This allows you to expand the Miniserver with many 1 Wire functions Details can be found on the ESERA website under Compatible controllers Control units Loxone integration https www esera de kompatible steuerungen zentralen loxone integration demo 1 wire controller 1 loxone in...

Page 12: ...tain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged Live cables or wires to which the device or an assembly is connected must always be tested for insulation faults or breaks If an error is detected in the supply line the device must be immediately taken out of operation until the faulty cable has been ...

Page 13: ... right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We develop our products further and we reserve the right to make changes and improvements to any of the products described in this documentation witho...