Software
•
Enter the firmware file-name (per
-button or per manual input)
◦
Do not change the
FoE password
(0). The
FoE filename
will be automatically generated
according to the file name (this has to start with
firmwareUpdate
as mentioned
above)
•
Activate the button
Download to device
to start the transmission
•
Wait until the file is transferred (see progress bar)
•
The “Flash” LED (yellow) is on while the update of the ECX-EC is in progress.
•
End of the update
◦
The LED “Status” (green) flickers:
▪
Update was successful. Disconnect the power supply voltage for approximately
5 seconds to restart the ECX-EC
◦
The LED “EC-A Error” (red) flickers:
▪
Update failed. Read the error code from the “AL Statuscode” register and contact
our support.
◦
In all other cases the transfer of the file to the ECX-EC has failed and the update has
not been started.
▪
Try to transfer the file again. If the transfer of the file fails again, the file might be
defective. Contact the support (
6.4.2 Firmware-Update with Beckhoff TwinCAT/Configurator
•
Connect the primary side of the ECX-EC with the TwinCAT system and choose
Scan
Boxes
(see Fig. 12).
•
Select the slave and click the button
Boostrap
on the tab
Online
in the field
State Machine.
Fig. 27:
Choose Bootstrap state via TwinCAT
◦
(If the slave remains in “Init” state either the secondary side is in “SafeOp/Op” or the
selected slave is the secondary side itself)
Page 64 of 74
Manual • Doc. No.: E.3022.21 / Rev. 1.9
ECX-EC