ESD CPCI-PN-DEV Manual Download Page 1

CPCI-PN-DEV

PROFINET

®

 IO /CompactPCI

®

 Interface

Manual

to Product I.2329.02

CPCI-PN-DEV

Manual • Doc. No.: I.2329.21 / Rev. 1.3

Page 1 of 30

                                                                esd electronics gmbh
             Vahrenwalder Str. 207 • 30165 Hannover • Germany
                                                                   http://www.esd.eu   
Phone: +49 (0) 511 3 72 98-0 • Fax: +49 (0) 511 3 72 98-68

Summary of Contents for CPCI-PN-DEV

Page 1: ...tPCI Interface Manual to Product I 2329 02 CPCI PN DEV Manual Doc No I 2329 21 Rev 1 3 Page 1 of 30 esd electronics gmbh Vahrenwalder Str 207 30165 Hannover Germany http www esd eu Phone 49 0 511 3 72...

Page 2: ...nics gmbh Vahrenwalder Str 207 30165 Hannover Germany Phone 49 511 372 98 0 Fax 49 511 372 98 68 E Mail info esd eu Internet www esd eu This manual contains important information and instructions on s...

Page 3: ...st English manual 2014 02 11 1 1 Note about data safety added to Safety Instructions 2014 09 23 4 2 Description of LED Indication for LED L and B revised 9 New Chapter PROFINET IO Certificate 10 Chapt...

Page 4: ...on is directed exclusively towards personal qualified in control and automation engineering The installation and commissioning of the product may only be carried out by qualified personal which is aut...

Page 5: ...15 7 2 1 PNCTL_START 15 7 2 2 PNCTL_SEND 16 7 2 3 PNCTL_TAKE 16 7 3 Library and Application Software 17 7 4 Using the CPCI PN DEV with the TIA Portal V13SP1 19 7 4 1 Quick Start 19 7 4 2 Installation...

Page 6: ...a CompactPCI board in 3U format The 100 BASE TX PROFINET IO interface is compatible to IEEE802 3 and runs with 100 Mbit s The PROFINET IO interface is electrically isolated The module can be configur...

Page 7: ...tors 2 PCB View with Connectors Figure 2 PCB top view See also page 13 for signal assignment of the PROFINET IO connectors NOTICE Do not change the jumper setting CPCI PN DEV Manual Doc No I 2329 21 R...

Page 8: ...omputer and all connected peripheral devices monitor printer etc 2 Discharge your body as described above 3 Disconnect the computer from the mains If the computer does not have a flexible mains cable...

Page 9: ...en Force PROFINET IO Force blinking on request of the master LED530A L green Link PROFINET IO Link data exchange with PLC active LED530B B green Boot Application on CPCI PN DEV started LED530C P green...

Page 10: ...ion Link green off no PROFINET IO or Ethernet connection on PROFINET IO or Ethernet connection exists Activity yellow off no PROFINET IO connection flickering PROFINET IO connection active Table 2 Ind...

Page 11: ...NET IO Port 3 Port 4 Only for test and programming purposes X300 X540 7 pin Samtec RSM 107 02 L S JTAG interface 4 pin Samtec RSM 104 02 L S Debug console TTL level Temperature range 0 50 C ambient te...

Page 12: ...lling voltage Table 5 Data of the CompactPCI bus 5 4 PROFINET IO Number of interfaces 4 Standard IEEE 802 3 10BASE T 100BASE TX Bit rate 10 100 Mbit s Controller Integrated in CPU PHY Micrel KSZ8721BL...

Page 13: ...1 RxD Receive Data 7 8 S Shield The pins 1 2 3 and 6 are terminated Signal Description MDI0 MDI1 Data lines reserved for Gigabit applications Shield case shield connected with the front panel of the C...

Page 14: ...following sizes are provided 1 2 4 8 16 32 64 120 words with 16 bit Larger modules do not make sense because the ERTEC400 allows only consistency of up to 240 bytes per module Example 5 input modules...

Page 15: ...ET IO 7 2 1 PNCTL_START PNCTL_START Start PN Slave Input PNSTART node not used only for compatibility reason Output PNSTART baud not used only for compatibility reason PNSTART buf_out_len Len of outpu...

Page 16: ...No data transferred Description Transmit the input process data to PROFINET IO 7 2 3 PNCTL_TAKE PNCTL_TAKE Read input data PN Master Outputs Input PNDATA offset Byte offset in input buffer PNDATA len...

Page 17: ...n case t test strtoul optarg NULL 0 break case d device strtoul optarg NULL 0 break case n node strtoul optarg NULL 0 break case r timeDelay strtoul optarg NULL 0 break case h help return 1 argc optin...

Page 18: ...0x 08x n pnStatus if timeDelay delay timeDelay if count for i 0 i pnData len i pnData byte i while timeDelay break default printf Unknown test n return 0 static void dumpBuffer unsigned char buffer in...

Page 19: ...have to be complied in offline mode 2 Change into the project view of your TIA Portal 3 Install the GSDML file as described in chapter Installation of the GSDML File 20 4 Insert the CPCI PN DEV in yo...

Page 20: ...window Manage general station description files opens Figure 5 Window Manage general station description files If the path to the folder is not already entered in the input field Source path correctl...

Page 21: ...n files now Activate the corresponding check box to select a file see Figure 7 Click onto the button Install to confirm the selection Figure 8 Installation has been successful If the installation of t...

Page 22: ...Hardware catalog which is in the right part of the window Therefore choose Other field devices PROFINET IO Network Components esd electronic system design gmbh CPCI DEV PN CPCI DEV PN To import the de...

Page 23: ...device name to edit it Enter the new name and press the the Return key to confirm the entry Figure 13 Change device name Now click with the right mouse button on the new device name to open the contex...

Page 24: ...rresponding row and then click on the button Assign name Figure 15 Assign name The new name is assigned now as you see in Figure 16 and the status OK is shown in the table Figure 16 New name is assign...

Page 25: ...lect the required data structures and drag and drop them into the slots of the CPCI PN DEV Figure 18 Example for assigned slots Do not leave any free rows in the assignment of the slots The TIA Portal...

Page 26: ...following Figure 20 Download hardware detail Select your PLC PLC_1 here again and and further in the pull down menu Download to device and then Hardware configuration The Hardware is loaded now 7 4 7...

Page 27: ...device overview Figure 22 main window with device overview The CPCI PN DEV receives an output process image from the PLC in which all output elements are shown in the order as they are listed in the...

Page 28: ...Declaration of Conformity 8 Declaration of Conformity Page 28 of 30 Manual Doc No I 2329 21 Rev 1 3 CPCI PN DEV...

Page 29: ...PROFINET IO Certificate 9 PROFINET IO Certificate CPCI PN DEV Manual Doc No I 2329 21 Rev 1 3 Page 29 of 30...

Page 30: ...der information PDF Manuals Manuals are available in English and usually in German as well For availability of manuals see table below Please download the manuals as PDF documents from our esd website...