Hardware Installation
CAN-M.2/402-2-FD
Hardware Manual Doc.-Nr.: C.2074.21/ 1.0
Page 15 of 32
5 Hardware Installation
NOTICE
Read the safety instructions at the beginning of this document carefully, before
you start with the hardware installation!
WARNING
Hazardous Voltage - Risk of electric shock due to unintentional contact with uninsulated
live parts with high voltages inside of the system into which the CAN-M.2/402-2-FD is to
be integrated.
→
→
Disconnect all hazardous voltages (mains voltage) before opening the system.
Never carry out work while power supply voltage is switched on!
Ensure the absence of voltage before starting any electrical work.
NOTICE
Electrostatic discharges may cause damage to electronic components.
→
→
To avoid this, please discharge the static electricity from your body
before
you touch
the CAN-M.2/402-2-FD.
Furthermore, you should prevent your clothes from touching the CAN-M.2/402-2-FD,
because your clothes might be electrostatically charged as well.
Procedure:
1. Switch off your system and all connected peripheral devices (monitor, printer, etc.). Switch off
the connected CAN devices.
2. Discharge your body as described above.
3. If applicable, connect the CAN-PCIeMini/402-DSUB9 adapters to the CAN-M.2/402-2-FD via
the adapter cables.
Figure 7:
CAN-M.2/402-2-FD wit 2 adapters
Set or remove the CAN termination jumper on the adapter according to your needs.
4. Disconnect the system from the mains.
Make sure that no risk arises from the system into which the CAN-M.2/402-2-FD shall be
inserted.