![Esco invt GD350A Series Product Manual Download Page 224](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081224.webp)
GD350A series high-performance multifunction VFD
-219-
Function
code
Name
Description
Default Modify
Range: 0.0–2000.0V
P17.12
Digital input
terminal state
Displays current digital input terminal state of
the VFD.
0000–03F
Corresponds to HDIB, HDIA, S4, S3, S2 and
S1 respectively
0
●
P17.13
Digital output
terminal state
Displays current digital output terminal state of
the VFD.
0000–000F
Corresponds to RO2, RO1, HDO and Y1
respectively
0
●
P17.14
Digital adjustment
value
Displays the regulating variable of UP/DOWN.
Range: 0.00Hz–P00.03
0.00Hz
●
P17.15
Torque reference
value
Relative to percentage of the rated torque of
current motor, display torque reference.
Range: -300.0%–300.0% (motor rated
current)
0.0%
●
P17.16
Linear speed
0–65535
0
●
P17.17
Reserved
0–65535
0
●
P17.18
Counting value 0–65535
0
●
P17.19 AI1 input voltage
Displays input signal of AI1
Range: 0.00–10.00V
0.00V
●
P17.20 AI2 input voltage
Displays input signal of AI2
Range: -10.00V–10.00V
0.00V
●
P17.21
HDIA input
frequency
Displays input frequency of HDIA
Range: 0.000–50.000kHz
0.000
kHz
●
P17.22
HDIB input
frequency
Displays input frequency of HDIB
Range: 0.000–50.000kHz
0.000 kHz
●
P17.23 PID reference value
Displays PID reference value
Range: -100.0–100.0%
0.0%
●
P17.24 PID feedback value
Displays PID feedback value
Range: -100.0–100.0%
0.0%
●
P17.25 Motor power factor
Displays the power factor of current motor.
Range: -1.00–1.00
1.00
●