GD350A series high-performance multifunction VFD
-152-
Function
code
Name
Description
Default Modify
core of AM 1
P02.15
Rated power of SM
1
0.1–3000.0kW
Model
depended
◎
P02.16
Rated frequency of
SM 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
◎
P02.17
Number of pole
pairs of SM 1
1–128
2
◎
P02.18
Rated voltage of
SM 1
0–1200V
Model
depended
◎
P02.19
Rated current of SM
1
0.8–6000.0A
Model
depended
◎
P02.20
Stator resistance of
SM 1
0.001–
65.535Ω
Model
depended
○
P02.21
Direct-axis
inductance of SM 1
0.01–655.35Mh
Model
depended
○
P02.22
Quadrature-axis
inductance of SM 1
0.01–655.35Mh
Model
depended
○
P02.23
Counter-emf of SM
1
0–10000
300
○
P02.24
Reserved
0x0000–0xFFFF
0
●
P02.25
Reserved
0%–50% (of the motor rated current)
10%
●
P02.26
Overload protection
selection of motor 1
0: No protection
1: Common motor protection (with low-speed
compensation). As the cooling effect of a
common motor is degraded at low speed
running, the corresponding electronic thermal
protection value needs to be adjusted
properly, the low compensation indicates
lowering the overload protection threshold of
the motor whose running frequency is lower
than 30Hz.
2: Variable-frequency motor protection
(without low speed compensation). Because
the heat dissipation function for a variable-
frequency motor is not impacted by the
rotation speed, it is not necessary to adjust the
protection value at low speed running.
2
◎