![Esco invt GD350A Series Product Manual Download Page 156](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081156.webp)
GD350A series high-performance multifunction VFD
-151-
Function
code
Name
Description
Default Modify
of braking for
jogging to stop
P01.34 Delay to enter sleep 0–3600.0s
0.0s
○
P02 group––Parameters of motor 1
P02.00
Type of motor 1
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
◎
P02.01
Rated power of AM
1
0.1–3000.0kW
Model
depended
◎
P02.02
Rated frequency of
AM 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
◎
P02.03
Rated speed of AM
1
1–60000rpm
Model
depended
◎
P02.04
Rated voltage of
AM 1
0–1200V
Model
depended
◎
P02.05
Rated current of AM
1
0.8–6000.0A
Model
depended
◎
P02.06
Stator resistance of
AM 1
0.001–
65.535Ω
Model
depended
○
P02.07
Rotor resistance of
AM 1
0.001–
65.535Ω
Model
depended
○
P02.08
Leakage inductance
of AM 1
0.1–6553.5Mh
Model
depended
○
P02.09
Mutual inductance
of AM 1
0.1–6553.5Mh
Model
depended
○
P02.10
No-load current of
AM 1
0.1–6553.5A
Model
depended
○
P02.11
Magnetic saturation
coefficient 1 of iron
core of AM 1
0.0–100.0%
80.0%
○
P02.12
Magnetic saturation
coefficient 2 of iron
core of AM 1
0.0–100.0%
68.0%
○
P02.13
Magnetic saturation
coefficient 3 of iron
core of AM 1
0.0–100.0%
57.0%
○
P02.14
Magnetic saturation
coefficient 4 of iron
0.0–100.0%
40.0%
○