Installation and Application
|
15
The Model 3810/2 is provided with an RF bonding stud on both the front and rear
panels. The unit should be bonded to a ground plane in normal operation.
Connect the Model 3810/2 to the spectrum analyzer or EMI receiver through the
BNC connector.
Select the line to be monitored by the two-position selector switch. The line not
selected is internally terminated into 50 ohms. Switching between the two lines
will not generate transients.
Remove the BNC connection before disconnecting power.
Front Panel Connectors and Controls
L
INE
S
ELECT
S
WITCH
Model 3810/2 Front View
BNC
C
ONNECTOR
RF
G
ROUND