INTRODUCTION 2-4 0-5555
2.09 Duty Cycle
The rated duty cycle of a Welding Power Source, is a statement of the time it may be operated at its rated
welding current output without exceeding the temperature limits of the insulation of the component parts. To
explain the 10 minute duty cycle period the following example is used. Suppose a Welding Power Source is
designed to operate at a 60% duty cycle, 90 amperes at 23.6 volts. This means that it has been designed and
built to provide the rated amperage (90A) for 6 minutes, i.e. arc welding time, out of every 10 minute period
(60% of 10 minutes is 6 minutes). During the other 4 minutes of the 10 minute period the Welding Power
Source must idle and allowed to cool.
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150 160 170 180 190 200 210 220
WELDSKILL
205 AC/DC
Welding Current (AMPS)
SAFE OPERATING REGION
(TIG & STICK)
0
0
10
20
30
40
60
70
50
80
100
90
Duty Cycle (PERCENTAGE)
GTAW (TIG)
MMAW (STICK)
A-13990
Figure 2-1: WeldSkill 205AC/DC Duty Cycle