4 INSTALLATION
0463 276 001
- 9 -
© ESAB AB 2015
4
INSTALLATION
The installation must be carried out by a professional.
4.1
Location
Position the power source such that its cooling air inlets and outlets are not obstructed. Also
position the power source so that the air inlet does not get clogged with unwanted material.
4.2
Mains power supply
Make sure that the welding power source is
connected to the correct supply voltage and
that it is protected by the correct fuse rating.
The outlet shall have a protective earth
connection.
A. Rating plate with supply connection data
4.2.1
Recommended fuse sizes and minimum cable area
Arc 145
Mains voltage
230 V 1 - ± 10 %, 50/ 60 Hz
Mains cable area mm
2
3 G 1.5
Phase current I
1eff
(TIG)
10.8 A
Phase current I
1eff
(MMA)
16 A
NOTE!
Use the power source in accordance with the relevant national regulations.