5 OPERATION
0446 253 101
- 15 -
© ESAB AB 2020
WARNING!
Secure the equipment, especially if used on an uneven or sloping surface.
5.1
Recommended maximum current values for connection
cables set
At an ambient temperature of +25 °C and normal 10 minutes cycle:
Cable area
Duty cycle
Voltage loss per 10 m
100%
60%
35%
70 mm²
350 A
400 A
480 A
0.28 V / 100 A
95 mm²
400 A
500 A
600 A
0.21 V / 100 A
At an ambient temperature of +40 °C and normal 10 minutes cycle:
Cable area
Duty cycle
Voltage loss per 10 m
100%
60%
35%
70 mm²
310 A
350 A
420 A
0.30 V / 100 A
95 mm²
375 A
430 A
525 A
0.23 V / 100 A
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading.