ESAB 0446 225 880 Instruction Manual Download Page 1

Instruction manual

0463 609 101 GB 20200110

Valid for: from serial no. 905-xxx-xxxx

EAC 10 Control unit

Summary of Contents for 0446 225 880

Page 1: ...Instruction manual 0463 609 101 GB 20200110 Valid for from serial no 905 xxx xxxx EAC 10 Control unit...

Page 2: ......

Page 3: ...TION 10 5 1 Control pendant 10 5 2 Connections 11 5 2 1 Connecting to digital power source 12 5 2 2 Connecting to compatible DC analogue power source 13 5 3 USB connection 14 5 3 1 Insert the USB memo...

Page 4: ...y precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All w...

Page 5: ...ELECTRIC AND MAGNETIC FIELDS Can be dangerous to health Welders having pacemakers should consult their physician before welding EMF may interfere with some pacemakers Exposure to EMF may have other he...

Page 6: ...uipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic...

Page 7: ...instruction manuals for the power source ESAB accessories for the product can be found in the ACCESSORIES chapter of this manual 2 1 Equipment EAC 10 can be connected to ESAB CAN based digital and co...

Page 8: ...nections adapted for ESAB motors 6 A 100 Speed control Feedback from pulse encoder Operating temperature 10 to 40 C 14 to 104 F Storage temperature 20 to 55 C 4 to 131 F Relative air humidity Max 95 D...

Page 9: ...4 INSTALLATION 0463 609 101 9 ESAB AB 2020 4 INSTALLATION The installation must be executed by a professional...

Page 10: ...1 Control pendant See separate instruction manual for description of the features of the control panel 1 Welding stop 8 Manual travel motion direction 2 Welding start 9 Fast motion 3 Welding current W...

Page 11: ...r carriage 2 On Off switch 7 Connection digital power source 3 Connection work piece voltage reference brush 8 Connection anlogue power source 4 Accessory cable entries 9 Cable to control pendant 5 Co...

Page 12: ...connection cable between CAN based ESAB power source and EAC 10 are available as accessories in different lengths ESAB CAN based power sources are LAF xxx1 TAF xxx1 and Aristo 1000 For further informa...

Page 13: ...e is connected Requirements on the analogue power source Supply voltage 60 V DC or 42 V AC 50 60 Hz from welding power source or by external means Voltage feedback from negative welding terminal for w...

Page 14: ...chapter ACCESSORIES 5 3 USB connection The external USB memory can be used to transfer programs to and from the control panel The USB memory must be formatted as FAT 32 in order to work During normal...

Page 15: ...ION All warranty undertakings from the supplier cease to apply if the customer attempts any work to rectify any faults in the product during the warranty period 6 1 Inspection and cleaning Check regul...

Page 16: ...standards EN 60974 1 and EN 60974 10 On completion of service or repair work it is the responsibility of the person s performing the work to ensure that the product still complies with the requirement...

Page 17: ...indicator BR1 Rectifier bridge C2 Filter capacitor S1 Power switch X1 Terminal block XP1 Connector for digital power source XP2 Connector for analogue power source XP3 Connector for carrier XP4 Connec...

Page 18: ...DIAGRAM 0463 609 101 18 ESAB AB 2020 Digital power source...

Page 19: ...DIAGRAM 0463 609 101 19 ESAB AB 2020 Analogue power source...

Page 20: ...AB 2020 ORDERING NUMBERS Ordering number Denomination Type Notes 0446 225 880 Control unit EAC 10 0463 612 Control panel instruction manual 0463 611 001 Spare parts list Technical documentation is ava...

Page 21: ...ce voltage reference brush 0446 146 880 5 m 16 ft 0446 146 881 15 m 49 ft 0446 146 882 25 m 82 ft 0446 146 883 35 m 115 ft 0446 146 884 50 m 164 ft 0446 146 885 75 m 246 ft Control cable EAC 10 ESAB a...

Page 22: ...85 100 m 328 ft Control cable for welding power source interface general analogue controlled power source 0446 157 880 Cable with 14 pin MS3106 20 27PX plug Suitable for power sources Lincoln Flextec...

Page 23: ...ACCESSORIES 0463 609 101 23 ESAB AB 2020...

Page 24: ...For contact information visit esab com ESAB AB Lindholmsall n 9 Box 8004 402 77 Gothenburg Sweden Phone 46 0 31 50 90 00 http manuals esab com...