Instalacion_77.fm -
28/7/11
INSTALLATION
48
Installation manual
Long operator, outward opening
Opening
angle
Dimension
A
Dimension
B
80º
200
235
85º
180
230
90º
165
225
90º
195
200
95º
160
215
100º
140
215
110º
140
195
i
Use of the chart:
For a specific opening angle, multiple A-B pairs can
be chosen. Generally, one of them will be
determined by the characteristics of the installation
(size of the pillar, presence of walls, etc).
1
Select the specified dimension in the chart.
2
Following the grid, move from the dimension to
the line corresponding to the required opening
angle.
3
Following the grid, move to the other
dimension.