VIVO-I103(M)/ VIVO-I203(M)

Quick installation and programming guide

English

 

 

  

WARNING

This quick guide is a summary of the complete installation manual. The manual contains safety warnings and
other explanations which must be taken into account. The most recent versions of this guide and the
installation manual are available at the "Downloads" section on Erreka's website. 

http://www.erreka-automation.com

The options and functions described in this guide apply for the firmware version indicated on the circuit. The
firmware, as part of a process of continuous improvement, is subject to new functionalities or upgrades being
included as a result of new versions which are not necessarily compatible with previous ones. For this reason,
some options or functions may differ or be unavailable if your firmware is older than shown in this guide.

Electrical wiring
A

:

Main power supply

B/F

: Flashing light with antenna

C

:

Photocells (Rx/Tx)

D

:

Key  switch

E

:

Operator

Elements of the complete installation

NOTE

: this control panel is valid for operators

for the following types of door and gate: 
swing (

C301

), 

sliding (

C302

),

up-and-over (

C303

).

VERY IMPORTANT: the 

TC

 closing stopper and the 

TA

opening stoppers must be installed.

VIVO-I203:

VIVO-I203M:

230V, 50-60Hz

125V, 50-60Hz

S.EXT./

  S.CIE.

S.INT./

  S.APE.

A.P./C.

A.T./A.

P294Z2

F2

F1

DL27

JP1

3~

M

1~

M

JP1

Pos 1

Pos 2

230V

230V

Power supply and peripheral cabling (valid for all cases)

(resistive)

(resistive)

F1

: 3A fuse

F2

: 0.5A fuse

DL27

: LED Continuous 

Bus

EPS1

: traffic light card

(with parameter 

Ab00

) or

b r a k e   c a r d   ( w i t h
p a r a m e t e r  

A b 0 1

,   s e e

connection diagram on
p a g e   1 2 ) .   S e e   o t h e r
options on page 16.

See the Display 
indications on 
page 12.

MSA

-115/00

Firmware V0.15 or later

Summary of Contents for VIVO-I103

Page 1: ...s or functions may differ or be unavailable if your firmware is older than shown in this guide Electrical wiring A Main power supply B F Flashing light with antenna C Photocells Rx Tx D Key switch E O...

Page 2: ...n GND common COM GND screen GND common COM SGN1 green or blue wire SGN1 opening FCA SGN1 green or blue wire SGN1 VUS operator safety micro SGN2 do not connect SGN2 closing FCC SGN2 white wire SGN2 ele...

Page 3: ...2 closing FCC SGN2 purple wire SGN2 do not connect SGN2 closing FCC G1 open G2 close G3 common In sliding gates C302 and up and over doors C303 it is only possible to use a single motor M1 which shoul...

Page 4: ...n Display indications In swing gates C4 refers to the interior photocell and C5 to the exterior photocell instead of opening and closing respectively D3 and D4 during operation 88 8 FT1 enabled 888 FT...

Page 5: ...ck of A2 operator turning direction C2 R294I 9 1 Press ENTER with the display showing CL88 or rSXX rS 8 rS 8 rS8 rS8 etc P294B 2 R294F 6 R294G 7 R294H 8 This procedure is the same as for operator A1 b...

Page 6: ...nd closing stopper must be installed before programming the travel see the operator manual 15 Start slowdown of leaf 2 with ST1 only with CA01 or CA03 I II U294R 16 Finish closing of leaf 2 with ST1 I...

Page 7: ...stalled 01 with single encoder 02 with limit switches 03 with dual encoder 04 with encoder and limit switches not available with C301 selected 05 VULCAN VUS and ATLAS ATS G6xxI only available with C30...

Page 8: ...op 03 automatic alternative stop if F200 is selected A903 becomes A902 A Lapse between leaves in opening and closing 0 9 0 9 22 00 no lapse in opening or closing apply only in gates with no overlap XY...

Reviews: