Network Camera User Manual
109
10.1.4
Configuring Alarm Output
Alarm Output Settings
Steps:
1.
Enter the Alarm Output Settings interface:
Configuration> Event > Basic
Event > Alarm Output
.
2.
Select one alarm output channel in the
Alarm Output
drop-down list. You can also
set a name for the alarm output (optional).
3.
The Delay time can be set to 5sec, 10sec, 30sec, 1min, 2min, 5min, 10min or
Manual
.
The delay time refers to the time duration that the alarm output remains in
effect after alarm occurs.
4.
Click
Arming Schedule
to enter the Edit Schedule Time
interface. The time
schedule configuration is the same as the settings of the arming schedule for motion
detection Refer to
Task 2: Set the Arming Schedule for Motion Detection
in
Section 10.1.1.
5.
You can copy the settings to other alarm outputs.