background image

Ernitec Mercury W301-S7 IP Demo Camera Quick Guide 

 

This guide is for quick installing and connecting the Mercury W301-S7 IP Dome Camera. For more details, please 
refer to the User

’s Manual of the camera in the supplied CD. 

 

Camera

’s Connectors (                                                                                                                                           

 

No. 

Connector 

Pin 

Definition 

Remarks 

RJ-45 

For network and PoE connections 

Power (DC 12V / AC 24V) 

AC 24V 1 

Power connection 

AC 24V 2 

GND 

DC 12V + 

BNC 

For analog video output 

Alarm & Audio I/O 

Alarm In 

– 

Alarm connection 

Alarm In + 

Alarm Out 

– 

Alarm Out + 

Audio Out R 

Audio line out 

Audio Out L 

Audio GND 

Audio In R 

Audio line in 

Audio In L 

microSD Card Slot 

Insert  the  microSD  card  into  the  card  slot  to  store  videos  and 
snapshots.  Do  not  remove  the  microSD  card  when  the  camera  is 
powered on. 

Default Button 

Press the button with one finger for at least 20 seconds to restore the 
system. 

 

NOTE:

 It is not recommended to record with the microSD card for 24/7 continuously, as it may not be able to 

support  long  term  continuous  data  read/write.  Please  contact  the  manufacturer  of  the  microSD  card  for 
information regarding the reliability and the life expectancy. 

 

Camera Cabling   

 

 

 

 

 

                                                                                                     

Please follow the instructions below for cable connections. 

 
Power Connection 

Please use a DC 12V / AC 24V power adaptor and plug it to the camera and the power outlet. Alternatively, users can 
use an Ethernet cable and connect it to the RJ-45 connector of the camera and a Power Sourcing Equipment (PSE) 
switch. 

 
NOTE:

 If PoE is used, make sure PSE is in used in the network. 

 

Ethernet Cable Connection 

Connect one end of the Ethernet cable to the RJ-45 connector of the camera, and plug the other end of the cable to 
the network switch or PC. 
 

NOTE:

 In some cases, Ethernet crossover cable might be needed when connecting the camera directly to the 

PC. 

NOTE:

 Check the status of the link indicator and activity indicator LEDs. If the LEDs are unlit, please check 

the LAN connection. 

 

 

Green Link Light indicates good network connection.   
Orange Activity Light flashes for network activity indication. 

 

 

No. 

Connector 

Pin 

Definition 

Remarks 

Audio I/O   

Pink 

Audio In 

Two-way audio transmission 

Green  Audio Out 

Alarm 
(4-Pin Terminal Block) 

Alarm In 

– 

Blue 

Alarm In + 

Green 

Alarm Out 

– 

Yellow 

Alarm Out + 

Orange 

Power (AC 24V) 

White 

AC 24 1 

Power connection 

Gray 

AC 24 2 

Power Jack (DC 12V) 

Power connection 

BNC 

For analog video output 

RJ-45 

For network and PoE connections 

-

 

Default Button 

Please refer to Default Button in the table under 

Camera

’s Connectors 

 

 

Before Login to the Camera                                                                                                                                               

 

A client program will be automatically installed  to the PC when connecting to the  camera. Before logging in to the 
camera,  please  ensure  downloading  the  ActiveX  control  is  allowed  by  either  changing  the  ActiveX  controls  and 
plug-ins  or  setting  Internet

’s  security  level  to  default.  For  further  details,  please  refer  to  the  User’s  Manual  in  the 

supplied CD. 

 

ActiveX Controls and Plug-ins Settings 

Internet Security Level 

Step 1:

  Start the Internet Explorer (IE). 

Step 2: 

Select  <Tools>  from  the  main  menu  of  the 

 

browser. Then click on <Internet Options>. 

Step 3: 

Click  on  the  <Security>  tab  and  select 

 

<Internet>,  and  click  on  <Custom  level>  to 

 

change ActiveX settings. 

Step 4: 

Set 

“ActiveX  controls  and  plug-ins”  items  to 

 

<Prompt> or <Enable>.

 

Step 1:

  Start the Internet Explorer (IE). 

Step 2: 

Select  <Tools>  from  the  main  menu  of  the 

 

browser. Then click on <Internet Options>. 

Step 3: 

Click  on  the  <Security>  tab  and  select 

 

<Internet>. 

Step 4:

   Down the page, click <Default Level> and click 

 

on  <OK>  to  confirm  the  setting.  Close  the 

 

browser window, and open a new one later for 

 

accessing the IP camera.

 

 
Camera Login 

 

 

 

 

 

 

                                                                                                           

 

 

The default IP address of the camera is: 

192.168.0.250

. Therefore, to access the camera for the first time, please set 

the IP address of the PC as: 192.168.0.XXX; for example: 

 

IP Address: 192.168.0.100 
Subnet Mask: 255.255.255.0 

 

Login ID and Password 

  Key in the camera

’s IP address in the URL bar of the web browser window and hit on “Enter”.   

  Enter the default username (

Admin

) and password (

1234

) in the prompt request dialogue. Note that username is 

case sensitive. 

 
Install the ActiveX Control 

  After connecting to the camera, the request for installing the ActiveX control will appear just below the URL bar. 

  Right  click  on  the  information  bar,  and  then  click  on  <Install  ActiveX  Control

…>  to  permit  ActiveX  control 

installation. 

 